A Valid and Reliable Virtual Reality Tool for Assessment of Arm Nonuse Post-Stroke
R. Gangwani, S. Zodrow, A. DeAngelis, M. Karrenbach, S. Kantak, L. J. Buxbaum
Key points
From the paper's conclusion- Discussion: The VR-NonUse tool is a reliable, valid, and practical assessment of arm nonuse in chronic stroke.
Abstract
Introduction: Approximately 40-80% of individuals post-stroke fail to use their paretic arm despite sufficient capacity, a phenomenon known as arm nonuse. This behavior arises from an interaction between cognitive and motor factors, necessitating evaluation approaches that capture the impact of complex task demands on arm nonuse. This study evaluated the validity, reliability, and usability of a virtual reality-based arm nonuse (VR-NonUse) tool designed to measure arm choice during naturalistic reaching under varying cognitive and motor demands. Methods: Fifty-one individuals with stroke and 23 controls completed the VR-NonUse assessment across three conditions varying in cognitive and motor demand. Arm choice was assessed on each trial. Usability and tolerability were evaluated. Concurrent validity was examined by assessing associations between paretic arm choice on the VR-NonUse tool and established nonuse assessments. Discriminant validity was evaluated by comparing these associations with a motor impairment measure. Construct validity was examined by determining the effects of cognitive and motor demand on paretic arm choice. Internal consistency reliability was assessed using a split-half reliability analysis with Spearman-Brown correction. Results: The VR-NonUse tool was usable, well-tolerated, and demonstrated high internal-consistency reliability. Paretic arm choice on the VR-NonUse tool was associated with established nonuse measures, and more strongly related to nonuse than to motor impairment, supporting concurrent and discriminant validity. Higher cognitive demand reduced paretic arm choice, supporting construct validity. A brief cognitively demanding condition yielded a robust index of nonuse. Discussion: The VR-NonUse tool is a reliable, valid, and practical assessment of arm nonuse in chronic stroke.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reliability, validity, and usability of an 18-item immersive virtual reality action research arm test: a validation study in stroke survivors.Frontiers in neurology · 2026
- Reliability and validity of virtual reality box & block test in healthy adults and patients with stroke: a prospective, multi-center, exploratory, cross-sectional studyJournal of NeuroEngineering and Rehabilitation · 2025
- Assessment of Upper Limb Function Using Virtual Reality Technologies in Adults with Neurological Disorders: A Systematic Review.Neurology international · 2026
- Usability, Acceptability, and Feasibility of a Personalized Adaptive Mirror Therapy for Upper-Limb Poststroke Rehabilitation Using Immersive Virtual Reality and Myoelectric Control: Single-Arm Pre-Post StudyJMIR Rehabilitation and Assistive Technologies · 2026
- Do we measure up? A systematic review of cognitive assessment during a digital era in acquired brain injury.Applied neuropsychology. Adult · 2026
- Immersive Virtual Reality for Stroke Rehabilitation: Linking Clinical and Digital Measures of Motor Recovery—A Pilot StudyBioengineering · 2026