AS-ULDAR: a ROS 2-based collaborative robotic platform for upper-limb rehabilitation - systems integration and pilot usability evaluation in a clinical environment.
Chiara Alessi, Nikolas Sacchi, Cira Fundarò, Antonella Ferrara
Department of Computer, Electrical, and Biomedical Engineering, University of Pavia, Pavia, Italy. · Neurophysiopathology Unit, Montescano Institute, Istituti Clinici Scientifici Maugeri IRCCS, Montescano, Italy.
Key points
From the paper's conclusion- These results show that integrating multiple rehabilitation functionalities is technically feasible, but that usability must be treated as a system-level property, and they provide concrete operational lessons for the clinical translation of cobot-based rehabilitation platforms.
Abstract
Robotic rehabilitation can increase the intensity and personalization of upper-limb therapy, but its clinical translation is hindered by the difficulty of integrating individually validated technical components into a single clinician-ready platform. This paper presents a platform which is intended to be an Auto-calibrating System for Upper Limb Disability Assessment and Rehabilitation (AS-ULDAR), a ROS 2-based platform built around a Franka Emika Panda robot that unifies motor/cognitive assessment, sensorless force estimation, and Cartesian and Human Joint-based Trajectory Tracking within a clinician-oriented GUI. While these functionalities were individually validated in prior work, the present contribution lies in their systems-level integration and in identifying the operational barriers that emerge when deploying such a platform in a real clinical workflow, targeting adult patients with chronic neurological conditions (stroke, Parkinson's, ALS, MCI) and mild-to-moderate upper-limb impairment. The platform was evaluated through a formative usability study: the standalone GUI by five naïve users, and the complete system by seven physiotherapists performing the full clinical workflow (no patients were involved; clinical efficacy is outside this scope). The system was technically stable throughout. Usability (SUS) was high for the GUI (87.5 ± 1.8) but markedly lower and more heterogeneous for the complete platform (54 ± 16), with feedback pointing to robot setup and workflow operation-not interface design-as the main friction points for clinical staff. These results show that integrating multiple rehabilitation functionalities is technically feasible, but that usability must be treated as a system-level property, and they provide concrete operational lessons for the clinical translation of cobot-based rehabilitation platforms.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- ARM-01: An Open-Source Reversible 2-DOF Upper-Limb Rehabilitation Robot with Internal Cable Routing and Intrinsic SafetyMendeley Data · 2026
- NeglectARm3D: a robotic and virtual reality platform for the three-dimensional assessment of unilateral spatial neglect.Frontiers in robotics and AI · 2026
- Measurement Uncertainty and Traceability in Upper Limb Rehabilitation Robotics: A Metrology-Oriented ReviewJournal of Sensor and Actuator Networks · 2026
- Bridging stakeholder needs and technological capabilities to identify humanoid robot applications in rehabilitation: a case study in an ALS multidisciplinary care unit.Frontiers in robotics and AI · 2026
- Upper Limb Neurorehabilitation Using a Hybrid Technology-Enabled Therapy Approach-A Scoping Review.NeuroRehabilitation · 2026
- Robot-assisted training for post-stroke lower-limb dysfunction: an umbrella review.Frontiers in public health · 2026