Simple and easy to build mechanical ventilator for pandemic health crises in resource-limited areas.
Ramon Farré, Raffaella Salama, Miguel A Rodríguez-Lázaro, Kasra Kiarostami, Laia Fernández-Barat, Viviane De Cassia Oliveira, Antoni Torres, Núria Farré,
Unitat de Biofisica i Bioenginyeria, Facultat de Medicina i Ciències de la Salut, Universitat de Barcelona, Barcelona, Spain. · CIBER de Enfermedades Respiratorias, Madrid, Spain.
Key points
From the paper's conclusion- Discussion Notwithstanding its limitations, this low-cost ventilator demonstrated adequate performance as a prototype.
Abstract
BACKGROUND: The COVID-19 pandemic exposed critical shortages of mechanical ventilators, particularly in low-resource settings. Disruptions in global supply chains and dependence on specialized components highlighted the need for scalable, locally manufacturing alternatives for emergency respiratory support. AIM: To describe and evaluate a simplified mechanical ventilator with minimal supply-chain dependence, assembled from widely available automotive and simple hardware components, and intended as a last-resort solution. METHODS: The ventilator is based on a reciprocating air pump driven by an automotive windshield wiper motor coupled to parallel shaft bellows and readily assembled passive membrane valves, only requiring materials available from standard hardware retailers, minimal tools, and basic manual skills. Ventilator performance was assessed through bench testing using a patient model simulating severe lung disease in an adult (R = 20 cmH₂O·s/L, C = 15 mL/cmH₂O) and pediatric (R = 50 cmH₂O·s/L, C = 10 mL/cmH₂O) patients. Realistic proof of concept was performed in four mechanically ventilated 50-kg healthy pigs. RESULTS: According to the bench test, the device delivered tidal volumes up to 600 mL and respiratory rates up to 45 breaths/min with PEEP up to 10 cmH₂O, covering most pediatric and adult ventilation ranges. The in vivo proof-of-concept showed that the ventilator maintained arterial blood gases within the targeted range. Technical details for ventilator construction are provided in an open-source video tutorial. DISCUSSION: Notwithstanding its limitations, this low-cost ventilator demonstrated adequate performance as a prototype. Although not a substitute for commercial intensive care ventilators, its simplicity, autonomy, and low dependence from fragile supply chains provides an approach towards life-saving options in resource-constrained emergency scenarios.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A network of syringe-injectable bioelectronics for closed-loop therapeutic rescue.bioRxiv : the preprint server for biology · 2026
- Design assessment and preliminary performance evaluation of a novel device for non-invasive emergency treatment of acute respiratory failure.Biomedical engineering letters · 2026
- Development and Evaluation of a System to Ventilate 2 Patients With a Single Ventilator.Military medicine · 2026
- Improved Suction Efficiency and User Satisfaction With a Novel Portable Manual Suction Device: A Simulation-Based Pre-Hospital Study.Inquiry : a journal of medical care organization, provision and financing · 2026
- A Portable Multi-Stream Telemedicine System for First-Level Emergency Support in Crisis EnvironmentsCurrent Directions in Biomedical Engineering · 2026
- An Intelligent Ventilation Bag Featuring Automated Pressure Control and Variable Oxygen RangeInternational Journal of Advanced Research in Science Communication and Technology · 2026