An Intelligent Ventilation Bag Featuring Automated Pressure Control and Variable Oxygen Range
Varsha G. Kulkarni, Vishal Borate, Dr. Yogesh Mali
Key points
From the paper's conclusion- The main objective is to develop a Smart Ventilation Bag with automated pressure adjustments and real-time oxygen monitoring.
Abstract
The COVID-19 pandemic highlighted the need for efficient and scalable respiratory support systems in emergency and critical care settings. Despite being widely used, manual ventilation bags provide challenges in ensuring consistent airflow, tidal volume, and real-time patient requirements adaption, especially when medical personnel utilize them for prolonged periods of time. The inability of manual Ambu bags to maintain a constant oxygen supply and pressure A new concept for a "Smart Ambu Bag" that combines an automated pressure regulating system with an adjustable oxygen concentration range is presented in this research. By tackling the challenges of manual breathing in emergency scenarios, the method aims to enhance accuracy and patient outcomes. The main objective is to develop a Smart Ventilation Bag with automated pressure adjustments and real-time oxygen monitoring. The Intelligent Ventilation Bag To measure the oxygen concentration in accordance with the patient's requirements, an oxygen sensor is incorporated into the air mix. When compared to existing manual and automated ventilators during COVID-19 situations, the Smart Ventilation Bag has the ability to bridge the gap between accessibility and performance, particularly in locations with limited resources. Better patient outcomes, less caregiver fatigue, and more reliable ventilation supply are demonstrated by simulation and experiment results. The study highlights how the Smart Ventilation Bag can assist expand the capacity for emergency respiratory care, paving the way for more scalable and reasonably priced respiratory support alternatives.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Manikin-based noninferiority simulation study of Airgency™: A novel automatic bag valve mask device for emergency respiratory support.Turkish journal of emergency medicine · 2026
- Beyond the Room: Bed-Level Isolation as Surge-Capable Infrastructure for Pandemics and Disasters-A Conceptual Framework.Disaster medicine and public health preparedness · 2026
- Design assessment and preliminary performance evaluation of a novel device for non-invasive emergency treatment of acute respiratory failure.Biomedical engineering letters · 2026
- Development and Evaluation of a System to Ventilate 2 Patients With a Single Ventilator.Military medicine · 2026
- Agreement and Reliability of a Newly Developed Tidal Volume Monitoring Device in Bag-Valve Ventilation and Intubation Scenarios: A Simulation-Based Study.Bioengineering (Basel, Switzerland) · 2026
- Automated Control of Oxygen Therapy: A State-of-the-Art Review of Closed-Loop Devices, with a Rule-Based, Network-Independent System (EMILY) as a Working Exemplar.Seminars in respiratory and critical care medicine · 2026