Feasibility of Laryngeal Mask Airway insertion during continuous chest compressions in neonatal resuscitation: a randomized crossover simulation study.
Cengizhan Yavuz, Emel Gündüz, Gözen Öksüz
Department of Anesthesiology and Reanimation, Kahramanmaraş Sütçü İmam University Faculty of Medicine, Kahramanmaraş, Türkiye. · Department of Anesthesiology and Reanimation, Akdeniz University Faculty of Medicine, Antalya, Türkiye.
Key points
From the paper's conclusion- These findings should be interpreted as a proof-of-concept rather than formal statistical equivalence.
Abstract
OBJECTIVE: The objective is to assess the times taken for laryngeal mask airway (LMA®) placement, successful LMA placement, successful ventilation, and minute air leak amounts during interrupted (Scenario A) and continuous (Scenario B) chest compressions during simulated neonatal resuscitation. MATERIAL AND METHODS: In this randomized crossover simulation study, participating physicians performed both scenarios in a randomly allocated sequence on a high-fidelity neonatal manikin. The evaluated parameters were LMA placement times, first-attempt placement success, minute ventilation (MV), air leak volume, device-related complications, and procedural difficulty scores (VAS). RESULTS: A total of 32 physicians (16 attending anesthesiologists and 16 senior residents) completed the study. No statistical difference was observed between Scenario A and Scenario B regarding LMA insertion times (10.47 ± 2.00 s vs. 10.28 ± 1.82 s; p > 0.05) and first-attempt success rates (100% vs. 96.9%). Minute ventilation remained at the 0.50 L/min target in 27 of 32 participants under Scenario B (median 0.50 L/min in both scenarios). Air leak was lower in Scenario B (0.186 ± 0.040 vs. 0.164 ± 0.029 L/min; p < 0.001). Median VAS difficulty scores did not differ significantly between scenarios (1.0 vs. 1.0; p = 0.159), and no complications were observed. Although a 1.0 s learning effect was detected in the analyses, this momentum was distributed symmetrically to the data due to the crossover design. CONCLUSION: In this simulated neonatal resuscitation model, LMA insertion during continuous chest compressions was feasible and maintained high first-attempt success. These findings should be interpreted as a proof-of-concept rather than formal statistical equivalence. The cause of the observed reduction in air leak under continuous compressions remains uncertain and may partly reflect instrument resolution limits rather than a true physiological effect. Furthermore, perceived procedural difficulty did not differ significantly between scenarios, and no device-related complications such as LMA folding or asymmetric chest rise were observed.Clinical Trial Registration: https://clinicaltrial.gov/, identifier NCT07681960.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Laryngeal Mask Airway: An Alternative for Neonatal Resuscitation in a US Safety-Net HospitalRespiratory Care · 2026
- Combined Use of Point-of-View (POV) Video and Mental Practice Training Versus Standard Demonstration for Neonatal Laryngeal Mask Airway Insertion by Novice Healthcare Professionals: A Randomized Simulation Study.Children (Basel, Switzerland) · 2026
- Effect of laryngeal mask airway versus endotracheal intubation on survival in out-of-hospital cardiac arrest: a meta-analysis of randomized controlled trials.Frontiers in public health · 2026
- Multiplying flow and pressure: detecting respiratory phases in intra-arrest ventilationResuscitation · 2026
- Feasibility of Prehospital Central Venous Cannulation During Cardiac Arrest in an Ambulance.Air medical journal · 2026
- Impact of real-time respiratory function monitoring on neonatal mask ventilation training: a multicentre simulation-based crossover study.BMJ paediatrics open · 2026