Laryngeal Mask Airway: An Alternative for Neonatal Resuscitation in a US Safety-Net Hospital
Danielle S. Roberts, Kirsten Gilliland, Cheri Sims, Carol Cavazos, Patricia Hagan, Karen Albrecht, Renee Starr, Laura J. Podewils
Health and Hospital Corporation · University of Colorado Anschutz Medical Campus
Key points
From the paper's conclusion- An evaluation of the feasibility, acceptability, and initial outcomes of implementing the laryngeal mask airway as the first-line approach for ventilation in late preterm and term infants was conducted in a high-resource, urban safety-net hospital with a level III neonatal intensive care unit (NICU).
Abstract
BACKGROUND: In the delivery room, newborn respiratory failure precedes cardiac failure, emphasizing the importance of effective ventilation. Face masks for ventilation may cause air leakage around the mask with subsequent suboptimal lung pressure, and intubation requires skilled providers. Laryngeal mask airways (LMA) may provide a more stable airway interface, with improved seal and more consistent ventilation that is less dependent on provider technique. An evaluation of the feasibility, acceptability, and initial outcomes of implementing the laryngeal mask airway as the first-line approach for ventilation in late preterm and term infants was conducted in a high-resource, urban safety-net hospital with a level III neonatal intensive care unit (NICU). METHODS: The LMA was introduced and promoted as the firstline for delivery room ventilation in infants ≥35 weeks gestational age and ≥1.5 kg from August 2023 to August 2024. Implementation was supported by comprehensive training, survey feedback, and multidisciplinary involvement. The program evaluation spanned a 2-year period from August 2022 to August 2024. Feasibility and acceptability data were collected via provider surveys, and neonatal outcomes were compared pre- and post-implementation from electronic health record data. RESULTS: During implementation, LMAs were used as first-line in 58.7% of eligible neonates indicated for delivery room ventilation. Provider surveys showed increased knowledge and confidence in LMA use after education and high comfortability with LMA implementation in the delivery room. NICU admission rates, delivery room endotracheal intubations, chest compressions, and epinephrine use were similar across groups. CONCLUSIONS: Providers across experience levels successfully inserted LMAs after brief training. LMA as first-line ventilation yielded similar outcomes to face mask in an urban safety-net hospital. Future research should explore broader applicability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Feasibility of Laryngeal Mask Airway insertion during continuous chest compressions in neonatal resuscitation: a randomized crossover simulation study.Frontiers in pediatrics · 2026
- Airway management and postoperative respiratory recovery after intravitreal injection in preterm infants.Pediatric research · 2026
- Impact of real-time respiratory function monitoring on neonatal mask ventilation training: a multicentre simulation-based crossover study.BMJ paediatrics open · 2026
- Effect of laryngeal mask airway versus endotracheal intubation on survival in out-of-hospital cardiac arrest: a meta-analysis of randomized controlled trials.Frontiers in public health · 2026
- Utilizing Low-Dose High-Frequency Simulation Training to Improve Neonatal Mask Ventilation in the Delivery Room.Joint Commission journal on quality and patient safety · 2026
- Laryngeal Mask Airway-Guided Fiberoptic Tracheal Intubation After Traumatic Failed Intubation in a Neonate With Severe Arthrogryposis Multiplex Congenita: A Case Report.Cureus · 2026