Perioperative nursing care of a pediatric patient with 22q11.2 deletion syndrome (DiGeorge syndrome/velocardiofacial syndrome) after receiving leadless pacemaker implantation: a case report
Dongqing Sun, Linyi Li, Mengxue Yang, Kaili Wei, Fan Wang, Hui Bai, Ping Fang, Bin Liu
Key points
From the paper's conclusion- Herein, we report the youngest documented case in China of successful leadless pacemaker implantation in a 4-year-old child presenting with third-degree atrioventricular block, who developed severe nickel-titanium hypersensitivity following three prior conventional pacemaker implantations.
Abstract
Leadless pacemaker implantation represents an emerging therapeutic alternative for patients ineligible for conventional pacing systems; nevertheless, clinical experience in young children remains scarce. Individuals with 22q11.2 deletion syndrome (DiGeorge syndrome/velocardiofacial syndrome) are susceptible to conduction abnormalities and severe hypersensitivity reactions to transvenous pacing devices. Herein, we report the youngest documented case in China of successful leadless pacemaker implantation in a 4-year-old child presenting with third-degree atrioventricular block, who developed severe nickel-titanium hypersensitivity following three prior conventional pacemaker implantations. This case report describes our perioperative nursing management and provides clinical insights to facilitate care for similarly complex paediatric patients.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Contemporary Advances of Leadless Pacing and Conduction System Pacing in Children With Congenital Heart Disease.Pacing and clinical electrophysiology : PACE · 2026
- Repeated epicardial lead dislodgement in a child with trisomy 21 and complete atrioventricular block: A case report.Journal of cardiology cases · 2026
- Successful atrial leadless pacemaker implantation in an 11-year-old with congenital sinus node dysfunction: a case report.European heart journal. Case reports · 2026
- Pacemakers in Pediatric Patients.Cardiology in review · 2026
- Two Is Not too Small; a Case of a Ventricular Aveir AR2 for Ventricular Pacing in a 12.2-kg Two-Year-Old.Pediatric cardiology · 2026