European heart journal. Case reports

Successful atrial leadless pacemaker implantation in an 11-year-old with congenital sinus node dysfunction: a case report.

Fredy Chipa-Ccasani, José Cruzalegui, Bosco Moscoso, José María Tolosana, Georgia Sarquella-Brugada

Arrhythmias, Inherited Cardiac Diseases and Sudden Death Unit, Hospital Sant Joan de Déu, Passeig de Sant Joan de Déu 2, Esplugues de Llobregat 08950, Spain. · European Reference Network for Rare, Low Prevalence and Complex Diseases of the Heart (ERN GUARD-Heart), 1105 AZ Amsterdam, The  Netherlands.

Case report

Key points

From the paper's conclusion
  • The patient met Class I criteria for permanent pacemaker implantation according to current paediatric pacing consensus recommendations, given symptomatic sinus node dysfunction with chronotropic incompetence.

Abstract

BACKGROUND: Sinus node dysfunction (SND) is rare in the paediatric population. Leadless atrial pacing represents a novel therapeutic option. To our knowledge, this case represents the youngest reported patient to receive an atrial leadless pacemaker (AVEIR AR). While ventricular leadless pacing has been described in children, atrial leadless pacing experience in this population remains extremely limited. CASE SUMMARY: An 11-year-old boy with lifelong bradycardia documented since fetal life presented with exertional dyspnoea and recurrent syncopal episodes. Electrocardiography revealed nodal rhythm without sinus activity. Electrophysiological evaluation demonstrated a corrected sinus node recovery time of 4800 ms and absence of chronotropic response to intravenous atropine (0.04 mg/kg IV). The patient met Class I criteria for permanent pacemaker implantation according to current paediatric pacing consensus recommendations, given symptomatic SND with chronotropic incompetence. An AVEIR AR leadless pacemaker was successfully implanted at the base of the right atrial appendage with optimal electrical parameters. No procedural or 18-month follow-up complications were observed. DISCUSSION: This case demonstrates procedural feasibility of atrial leadless pacing in a carefully selected paediatric patient, with encouraging mid-term follow-up. Larger studies are required to establish long-term safety and clinical outcomes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers