Quantifying the impact of model choice on personalized radiotherapy planning for high-grade gliomas using mathematical modeling

Tarini Thiagarajan, Thomas E. Yankeelov, Bikash Panthi, Sara Thrower, Karine A. Al Feghali, Andrew M. Elliott, Holly Langshaw, Caroline Chung,

Key points

From the paper's conclusion
  • Results The personalized dose maps that utilized maximum median doses of 2.65 Gy/fraction and 3.97 Gy/fraction for M V and M C , respectively, were associated with significantly greater median predicted reductions in total tumor cell count of 8.10% to 52.23% ( P < 0.05) relative to the standard-of-care plan.

Abstract

Introduction Conventional radiotherapy (RT) planning targets tumors assuming uniform treatment effectiveness, a fundamental limitation when treating high-grade gliomas, which are biologically heterogeneous tumors. To better understand the effects of intratumoral heterogeneity on predicted outcomes, we retrospectively evaluated the impact of model assumptions on the predicted effects of RT. Methods We considered three biology-based mathematical models that assume 1) homogeneous RT efficacy across the tumor ( M H ), 2) heterogeneous RT efficacy based on vasculature ( M V ), and 3) heterogeneous RT efficacy based on cell density ( M C ). All three models were integrated within a reaction-diffusion framework with RT response governed by the linear-quadratic model. Each model was retrospectively calibrated to each patient’s ( N = 9) longitudinal multiparametric MRI data (pre- and post-contrast T 1 -weighted, T 2 -weighted Fluid-Attenuated Inversion Recovery, and diffusion-weighted MRI) collected before and after RT. The personalized model parameters (e.g., tumor cell proliferation rates, diffusion coefficients, mechanical coupling coefficients, and surviving fractions (SFs)) were used to simulate RT response across a range of SFs for each model. For M V and M C , we then determined the radiation dose boost required to achieve a globally defined target SF. Results The personalized dose maps that utilized maximum median doses of 2.65 Gy/fraction and 3.97 Gy/fraction for M V and M C , respectively, were associated with significantly greater median predicted reductions in total tumor cell count of 8.10% to 52.23% ( P < 0.05) relative to the standard-of-care plan. To assess the relative contributions of spatial dose targeting and dose boosting to the predicted improvements in tumor control, we simulated RT response using uniform dose boost maps that delivered the same total radiation dose as the corresponding personalized dose maps. This comparison showed that personalized dose maps resulted in modest improvements in predicted tumor control for M V at mid-to-high target SFs, whereas uniform boosting resulted in slightly greater predicted reductions in total tumor cell count for M C at high target SFs. Discussion These results demonstrate the potential of achieving greater radiation treatment effects through alternate treatment response models that inform personalized dose escalation strategies based on individualized predictions of treatment outcomes, while also showing that the additional benefit of spatial targeting is model-dependent.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Quantifying the impact of model choice on personalized radiotherapy planning for high-grade gliomas using mathematical modeling — Science Skim