Towards a clinically practical computational platform for systematically adapting radiation therapy for glioma patients.
Hugo Joseph Michel Miniere, David Hormuth, Ernesto Augusto Bueno da Fonseca Lima, Thomas Whitaker, Maguy Farhat, Bikash Panthi, Holly Langshaw, Mihir Shanker,
Biomedical Engineering, The University of Texas at Austin, 2515 Speedway, Austin, Texas, 78712-1139, United States. · Oden Institute for Computational Engineering and Sciences, The University of Texas at Austin, 2515 Speedway, Austin, Texas, 78712-1139, United States.
Key points
From the paper's conclusion- We address this limitation by guiding radiation delivery using imaging data to identify proliferative areas which are then targeted by a dose boost, and use mathematical modeling to simulate treatment response between the adjusted and the SOC treatment plan.

Approach: Quantitative MRI data for 15 HGG patients were collected at baseline and the third week of treatment to identify regions o
Abstract
High-grade gliomas (HGG) are aggressive brain tumors with poor prognoses despite an intense standard-of-care (SOC) chemoradiation protocol. Radiotherapy guidelines use static dose maps, which may not fully account for intratumoral heterogeneities and areas of tumor progression over the course of treatment. We address this limitation by guiding radiation delivery using imaging data to identify proliferative areas which are then targeted by a dose boost, and use mathematical modeling to simulate treatment response between the adjusted and the SOC treatment plan. Approach: Quantitative MRI data for 15 HGG patients were collected at baseline and the third week of treatment to identify regions of high proliferation to guide the adapted radiation dose plan. The resulting dose plan is then adjusted by a board-certified medical physicist to ensure deliverability using clinically available linear accelerators. The plans are then used to virtually "treat" each patient via our biology-based mathematical model, individually calibrated to each patient's imaging data acquired prior to dose adaptation. Main results: Our adaptation pipeline predicted a median (range) decrease in tumor burden of 31% (12%, 57%) one month post-therapy across the patient cohort compared to the SOC predicted tumor burden (p < 0.05). After adjusting the dose plan for clinical deliverability, it still predicted a decrease in tumor burden of 30% (7%, 62%) which is also significantly different than the SOC protocol (p < 0.05). Significance: Our clinical-computational platform, integrating mathematical modeling, dose painting, and adaptive radiotherapy, can identify alternative radiation dose plans hypothesized to yield statistically greater tumor control than the SOC prescriptions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quantifying the impact of model choice on personalized radiotherapy planning for high-grade gliomas using mathematical modelingFrontiers in Oncology · 2026
- Patient-Specific Computational Framework to Spatiotemporally Forecast Treatment Response and Identify Biologically Informed Radiotherapy Targets in High-Grade Glioma.JCO clinical cancer informatics · 2026
- 593 Survival and Toxicity Outcomes of Metabolic Imaging–Guided Radiotherapy Dose Escalation in Glioblastoma: A Systematic Review and Meta-AnalysisNeuro-Oncology Advances · 2026
- CNSC-47 An image-informed mechanistic model to predict brain metastases growth and therapy responseNeuro-Oncology · 2026
- 92 Different therapeutic approaches in newly diagnosed glioblastoma and their impact on overall survival: a systematic review and meta-analysisNeuro-Oncology Advances · 2026
- Dynamic image-informed selection of biomechanical tumor growth models.Biomechanics and modeling in mechanobiology · 2026