Neuro-Oncology

RADT-38 Genomic adjusted radiation dose enables biologically personalized radiotherapy in glioblastoma

Peng Chen, Nikhil Joshi, Drew Bergman, Shivani Nellore, Steven Eschrich, Javier Torres-Roca, Jacob Scott

Key points

From the paper's conclusion
  • Here, we evaluated whether GARD predicts radiotherapy response and assessed RxRSI as a framework for dose personalization in GBM.

Abstract

Background Radiotherapy is a cornerstone of glioblastoma (GBM) treatment, yet dose selection relies on population-level standards rather than tumor-intrinsic radiosensitivity. The radiosensitivity index (RSI) characterizes tumor-specific radiation sensitivity, the derived genomic-adjusted radiation dose (GARD) quantifies the biological effect of a delivered dose, and the biologically optimized prescription dose (RxRSI) estimates the patient-specific dose required to achieve a target biological effect. Here, we evaluated whether GARD predicts radiotherapy response and assessed RxRSI as a framework for dose personalization in GBM. Methods We evaluated 158 GBM tumor samples treated with radiotherapy (45–70 Gy) from TCGA, with RSI derived from RNA-sequencing. Associations between GARD and overall survival (OS) were assessed using Cox proportional hazards and Kaplan-Meier analyses. Subgroup analyses were stratified by MGMT promoter methylation status and age to assess whether radiosensitivity heterogeneity tracked with established prognostic biomarkers. Results GBM patients demonstrated substantial variability in the expected biological effect of radiotherapy independent of physical dose administered (GARD range: 3 – 42). Kaplan-Meier analysis demonstrated improved OS in GARD-high versus GARD-low patients (1-year OS: 85% versus 65%, p = 0.03). In multivariable Cox analysis, continuous GARD was independently associated with OS (HR 0.94, 95% CI 0.89–0.98; p = 0.01). GARD heterogeneity was observed across MGMT methylation and age subgroups. RxRSI modeling suggested 53.8% of patients would benefit from dose escalation and 9.5% from de-escalation relative to standard dosing. Conclusions GBM patients demonstrated substantial variability in the expected biological effect of radiotherapy independent of physical dose delivered. GARD heterogeneity suggests that tumor radiosensitivity may provide prognostic information beyond currently used clinical and molecular markers. RxRSI modeling suggests individualized dose strategies may optimize biological effect, supporting prospective investigation of genomically informed radiotherapy personalization in GBM.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers