Novel Bragg peak FLASH radiotherapy: treatment of base-of-skull tumors within existing clinical guidelines.
Michael Pennock, Balaji Selvaraj, Chingyun Cheng, Alex Kyler, Haibo Lin, Shaakir Hasan, Arpit Chhabra, Jehee Isabelle Choi,
Department of Radiation Oncology, University of Pittsburgh Hillman Cancer Center, Pittsburgh, PA, United States. · New York Proton Center, New York, NY, United States.
Key points
From the paper's conclusion- PBS Bragg peak FLASH can deliver conformal target dosimetric coverage, ultra-high dose rates, and comparable OAR dosimetry to CONV-IMPT, suggesting that this novel technique is feasible for BOS tumor FLASH radiotherapy. The study supports future research to explore FLASH's biological and clinical benefits in BOS tumors and OAR sparing.
Abstract
BACKGROUND AND PURPOSE: Proton therapy is commonly delivered for base-of-skull (BOS) tumors to minimize risk of normal-tissue injury. Novel Bragg peak FLASH may improve protection for organs at risk (OARs). We investigated if proton pencil-beam scanning (PBS) Bragg peak FLASH could achieve comparable dosimetry at ultra-high dose rates to conventional-rate (CONV)-intensity-modulated proton therapy (IMPT) for potential clinical use. MATERIALS AND METHODS: PBS Bragg peak FLASH and CONV-IMPT plans were optimized for 10 consecutive patients with BOS tumor in an in-house treatment-planning system and hypofractionation regimen (30 GyE in five fractions) to assess dosimetric quality while reflecting clinical practice, parameters, and hypothetical fraction doses for FLASH effect. FLASH dose-rate coverage (V 40Gy/s) and dose-rate volume histograms (DRVHs) were quantified across OARs. FLASH (≥40 Gy/s) was achieved with a minimum MU per spot of 300-500 and a minimum spot time (MST) of 0.5 ms. FLASH dose-rate coverage, OAR sparing, and target coverage were averaged across all cases. RESULTS: FLASH generated higher CTV D max than CONV-IMPT (114% vs. 108%). Dose metrics for OARs were comparable between modalities (p > 0.05). Average dose rate (ADR) DRVHs of OARs indicated 74.1% V 40Gy/s FLASH dose-rate coverage without dose threshold, and 94.4% V 40Gy/s FLASH dose-rate coverage with 1-Gy dose threshold. CONCLUSION: PBS Bragg peak FLASH can deliver conformal target dosimetric coverage, ultra-high dose rates, and comparable OAR dosimetry to CONV-IMPT, suggesting that this novel technique is feasible for BOS tumor FLASH radiotherapy. The study supports future research to explore FLASH's biological and clinical benefits in BOS tumors and OAR sparing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- In silico feasibility and robustness evaluation of a single-spot proton Bragg peak FLASH platform for small-animal irradiation using a generalized 3D-printed bolus.Physics in medicine and biology · 2026
- Single‐field‐uniform‐dose‐per‐fraction simultaneous dose and dose rate optimization (SFUDPF–SDDRO) method for proton FLASH therapyMedical Physics · 2026
- Proton Bragg peak flash stereotactic radiosurgery for recurrent glioblastoma reirradiation.Physics and imaging in radiation oncology · 2026
- A Proton Treatment Planning Method for Combining FLASH and Spatially Fractionated Radiation Therapy to Enhance Normal Tissue ProtectionIEEE Transactions on Radiation and Plasma Medical Sciences · 2026
- Analysis on radiation protection of FLASH treatment in conventional proton therapy facilities.Medical physics · 2026
- Advances in FLASH radiation therapy: A review on biological foundations and clinical prospectsTranslational Oncology · 2026