Proton Bragg peak flash stereotactic radiosurgery for recurrent glioblastoma reirradiation.
Yangguang Ma, Yuyu Wang, Tengda Zhang, Xingyi Zhao, Balaji Selvaraj, Chingyun Cheng, Michael Pennock, Jocelyn Jackson,
Radiotherapy Department, The First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China. · Faculty of Medical Sciences, University of Groningen, University Medical Center Groningen, the Netherlands.
Key points
From the paper's conclusion- This study evaluated the dose-volume characteristics of SEBP-FLASH and robotic image-guided systems and found broadly comparable dose distributions, suggesting that SEBP-FLASH may be a feasible option for rGBM reirradiation. SEBP-FLASH also showed potential advantages in conformity, normal tissue sparing, and reduced on-table time.
Abstract
BACKGROUND AND PURPOSE: Stereotactic Radiosurgery with robotic image-guided systems is promising for recurrent glioblastoma (rGBM), but long delivery times may increase morbidity and reduce accuracy. Proton single-energy Bragg-peak FLASH-RT (SEBP-FLASH) may address these limits by delivering each field in <1 s, with potential for normal-tissue sparing through the FLASH effect. MATERIALS AND METHODS: The SEBP-FLASH technique was used to reoptimize treatment for rGBM patients treated with robotic image-guided systems. Patient-specific aperture devices were incorporated into the SEBP-FLASH technique for sharper penumbra. The gross tumor volume (GTV) coverage, conformity index (CI), dose gradient index (GI50 and GI30), and dose-volume histogram (DVHs), were evaluated. Additionally, ultra-high dose-rate ratios in critical organs-at-risk were assessed. RESULTS: SEBP-FLASH successfully met all clinical objectives. Both SEBP-FLASH and robotic techniques showed comparable performance, with GI50 and GI30 values of 2.9 ± 0.5 and 6.2 ± 1.8 for SEBP-FLASH, versus 2.7 ± 0.2 and 5.5 ± 0.5 for robotic (p-values at 0.085 and 0.189). SEBP-FLASH demonstrated superior conformality, achieving a CI of 1.4 ± 0.2 compared to CK's 1.9 ± 0.3 (p-value 0.001). All other metrics were similar across both techniques. For the brain, the FLASH dose rate coverage (V40 Gy/s) exceeded 80% under a 5 Gy dose threshold and minimum monitor unit of 400. CONCLUSIONS: This study evaluated the dose-volume characteristics of SEBP-FLASH and robotic image-guided systems and found broadly comparable dose distributions, suggesting that SEBP-FLASH may be a feasible option for rGBM reirradiation. SEBP-FLASH also showed potential advantages in conformity, normal tissue sparing, and reduced on-table time.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Novel Bragg peak FLASH radiotherapy: treatment of base-of-skull tumors within existing clinical guidelines.Frontiers in oncology · 2026
- In silico feasibility and robustness evaluation of a single-spot proton Bragg peak FLASH platform for small-animal irradiation using a generalized 3D-printed bolus.Physics in medicine and biology · 2026
- A Proton Treatment Planning Method for Combining FLASH and Spatially Fractionated Radiation Therapy to Enhance Normal Tissue ProtectionIEEE Transactions on Radiation and Plasma Medical Sciences · 2026
- RADT-19 Hypofractionated Proton Reirradiation for Recurrent Glioblastoma: Clinical and Dosimetric Outcomes with Photon Comparison CohortNeuro-Oncology · 2026
- Reducing the dose delivered to major intracranial blood vessels in brain radiotherapy using spot-scanning proton arc therapy.Journal of applied clinical medical physics · 2026
- Tumor control probability and safety of reirradiation with stereotactic radiosurgery for local recurrence of brain metastases after prior stereotactic radiosurgery: a systematic review and meta-analysis.Radiation oncology (London, England) · 2026