Perceived sound quality and speech recognition are not interchangeable outcome measures in adult cochlear implant users.
Nadine Buczak, Michael F Dorman, Anke Leichtle, Andreas Büchner
Department of Otolaryngology, Hannover Medical School, Hannover, Germany. · College of Health Solutions, Arizona State University, Tempe, AZ, United States.
Key points
From the paper's conclusion- Conclusion Speech-recognition measures do not reliably capture perceived cochlear implant sound quality.
Abstract
INTRODUCTION: This study examined whether descriptor-based reports of perceived sound quality in adult cochlear implant users are associated with speech-recognition outcomes, preoperative maximum monosyllabic word recognition, and patient- or device-related factors. METHODS: In this retrospective single-center analysis, 249 adult cochlear implant users completed a 25-item descriptor-based sound-quality assessment covering retrospectively recalled early (T1) and current (T2) listening experience. Descriptor profiles and superordinate descriptor groups were linked to preoperative maximum monosyllabic word recognition and postoperative speech-recognition outcomes in quiet and noise using group comparisons, univariate logistic regression, and multiple linear regression of rank-transformed objective outcomes, with false-discovery-rate correction. RESULTS: Individual sound-quality descriptors were not robustly associated with concurrent or later speech-recognition performance. Preoperative maximum monosyllabic word recognition was not robustly associated with later descriptor profiles. Patient- and device-related factors showed selective associations with descriptor endorsement. Among nominally significant associations in adjusted models, descriptors and supergroups explained 1.5-3.2 percentage points of additional variance in speech-recognition outcomes and 1.8-3.3 percentage points in preoperative maximum monosyllabic word recognition beyond patient- and device-related factors. CONCLUSION: Speech-recognition measures do not reliably capture perceived cochlear implant sound quality. Structured sound-quality assessment may add clinically relevant information beyond standard speech testing, particularly when subjective listening experience and conventional outcome measures do not align.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sound quality, not speech recognition, explains cochlear implant-related quality of life outcomesJASA Express Letters · 2025
- Ten years of research on the sound quality of cochlear implants.Frontiers in human neuroscience · 2026
- From Approximation to Validation: Rethinking Frequency-Matched Acoustic Models of Cochlear Implants.Ear and hearing · 2026
- Individualized, precise threshold-level fitting improves speech recognition and loudness differentiation in cochlear implant users.Zeitschrift fur medizinische Physik · 2026
- Establishing reliable neural health measures in adult cochlear implant users.Frontiers in neuroscience · 2026
- Beyond speech perception: contemporary landscape of language agnostic hearing assessmentFrontiers in Neuroscience · 2026