Individualized, precise threshold-level fitting improves speech recognition and loudness differentiation in cochlear implant users.

Luise Wagner, Leonie Beier, Oliver Dziemba, Stefan K Plontke, Torsten Rahne

University Medicine Halle, Department of Otorhinolaryngology, Head and Neck Surgery, Halle (Saale), Germany. Electronic address: luise.wagner@uk-halle.de. · University Medicine Halle, Department of Otorhinolaryngology, Head and Neck Surgery, Halle (Saale), Germany.

Observational

Key points

From the paper's conclusion
  • Precise, individualized T-level fitting to the electrical hearing threshold enhances speech recognition and increases the percentage of CI users who achieve their predicted clinical outcomes.

Abstract

Precise fitting of threshold (T-) levels in cochlear implant (CI) sound processors is crucial for optimizing speech recognition and audibility for CI users. This study systematically investigated the effects of T-level fitting on speech recognition in quiet in adult CI users. Thirty-five adult, experienced CI users with a Nucleus system (Cochlear, Sydney, Australia) were included in a prospective exploratory study. T-levels for each electrode were individually fitted to each participant's electrical hearing threshold using a standardised adaptive procedure. Speech recognition at sound pressure levels of 50, 65, and 80 dB SPL and the Oldenburg Categorical Loudness Scaling (CLS) were measured, and the baseline and post-intervention values were compared. The preoperative outcome prediction for speech recognition was compared with the results obtained before and after the intervention. Precise T-level fitting to the electrical hearing threshold resulted in overall changes ranging from a reduction of 4.8CL to an increase of 9.9CL per electrode (mean: 0.5CL, SD: 15.7 CL). Mean monosyllabic word recognition improved significantly at all measured sound pressure levels. At 65 dB SPL, it increased from 64% to 74% (p < 0.001). With precise T-level fitting, more CI users achieved their preoperative outcome prediction for speech recognition. Precise, individualized T-level fitting to the electrical hearing threshold enhances speech recognition and increases the percentage of CI users who achieve their predicted clinical outcomes. Individualised, electrode-specific threshold adjustment is important for achieving an optimal CI outcome. Further research is needed to refine the threshold detection methods and fitting procedures for broad clinical application.

Read the paper