Ten years of research on the sound quality of cochlear implants.
Michael F Dorman, Sarah C Natale, Joshua S Stohl
Arizona State University, College of Health Solutions, Tempe, AZ, United States. · MED-EL North American Research Laboratory, Durham, NC, United States.
Key points
From the paper's conclusion- The final project established that muffled sound quality could be reduced by including an input gain for mid frequencies.
Abstract
This report summarizes data collected over the span of more than a decade from four laboratories on the sound quality of cochlear implants. Sixteen projects (ten published and six unpublished) are summarized; two video and eleven audio files accompany the summaries. Fourteen of the projects used single sided deaf patients (SSD) fit with an implant (CI) as listeners; one project used SSD-CI patients with preserved hearing (HP) in their implanted ear; one project used conventional CI patients. Approximately a third of the SSD-CI patients could create close matches to CI sound quality. The matches varied as a function of electrode length. Patients fit with shorter electrode arrays used upshifted formant frequencies and/or voice pitch and spectral smearing to match sound quality. Approximately half of the patients with longer electrode arrays used low- or band-pass filtering, spectral smearing and/or pitch contour flattening to match sound quality. Other patients chose very few modifications - these signals were relatively clean. For the SSD-CI/HP patients, stimulation directed to both the CI and acoustic hearing was characterized, relative to stimulation directed only to the CI, by one or more of the following: (i) a lower F0, (ii) a less flattened F0 contour, (iii) less upshift in formant frequencies, (iv) less smear, and (v) fewer instances of high-pass filtering. The final project established that muffled sound quality could be reduced by including an input gain for mid frequencies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Perceived sound quality and speech recognition are not interchangeable outcome measures in adult cochlear implant users.Frontiers in human neuroscience · 2026
- From Approximation to Validation: Rethinking Frequency-Matched Acoustic Models of Cochlear Implants.Ear and hearing · 2026
- Long-Term Auditory, Tinnitus, and Psychological Outcomes After Cochlear Implantation in Single-Sided Deafness: A Two-Year Prospective StudyJournal of Clinical Medicine · 2026
- Results for Adults with Asymmetric Hearing Loss Who Receive a Cochlear Implant.Audiology research · 2026
- The Effect of Etiology, Array Type and Duration of Deafness on Focused Detection Thresholds in Cochlear Implant Listeners.Trends in hearing · 2026
- A Nordic cohort study on cochlear implants and binaural hearing in single-sided deafness.Acta oto-laryngologica · 2026