Key points
From the paper's conclusion- Conclusion T1-CUBE-DLS reduces acquisition time by 36.2%, with no significant difference in diagnostic accuracy detected, while improving enhancement conspicuity and measurement reproducibility, supporting its potential as a practical and efficient alternative for ON evaluation.
Abstract
OBJECTIVE: To compare a deep learning-accelerated contrast-enhanced 3D T1-weighted sequence (T1-CUBE-DLS) with standard parallel imaging-accelerated T1-CUBE for detecting acute optic neuritis (ON). METHODS: This prospective study enrolled 59 patients with suspected acute ON (38 females; mean age 41.2 ± 12.8 years). All underwent contrast-enhanced whole-brain 3.0 T MRI including both T1-CUBE-DLS and standard T1-CUBE sequences. Two blinded neuroradiologists independently scored motion artifacts, subjective noise, and optic nerve clarity. Consensus readings recorded enhancement laterality, involved segments, and visual conspicuity. Enhancement length was measured per optic nerve, with inter-observer reliability assessed via intraclass correlation coefficient (ICC) and Bland-Altman analysis. Clinical diagnosis by a senior neuro-ophthalmologist served as the reference standard. RESULTS: Acute ON was confirmed in 43 of 59 patients (72.9%). T1-CUBE-DLS reduced acquisition time by 36.2%. Subjective noise was equivalent between sequences (p > 0.05), but T1-CUBE-DLS showed significantly fewer motion artifacts and superior optic nerve clarity (both p < 0.05). No significant difference was detected in diagnostic performance between the two sequences: sensitivity (88.4% vs. 86.0%), specificity (93.8% vs. 93.8%), and accuracy (89.8% vs. 88.1%; all p > 0.05). T1-CUBE-DLS demonstrated stronger visual conspicuity (p = 0.011) and slightly longer measured enhancement length (mean difference, 0.836 mm; p < 0.0001). ICC for length measurement was 0.91 for T1-CUBE-DLS vs. 0.83 for standard T1-CUBE, with narrower 95% limits of agreement (-1.37 to 1.51 mm vs. - 3.1 to 2.4 mm). CONCLUSION: T1-CUBE-DLS reduces acquisition time by 36.2%, with no significant difference in diagnostic accuracy detected, while improving enhancement conspicuity and measurement reproducibility, supporting its potential as a practical and efficient alternative for ON evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical Evaluation of Deep Learning–Reconstructed Postcontrast 3D T1-Weighted Volume Interpolated Breath-Hold Examination (VIBE) Compared with Standard VIBE for Detection of Internal Auditory Canal LesionsAmerican Journal of Neuroradiology · 2026
- Image quality evaluation of dual deep learning accelerated post-contrast Magnetization Prepared Rapid Gradient Echo (MPRAGE) imaging at 1.5 T and 3 T MRI.Acta radiologica (Stockholm, Sweden : 1987) · 2026
- Deep Learning-Accelerated 3D T2 CUBE MRI of the Cochlea at 1.5T and 3T: Sonic DL With AIR Recon DL Versus AIR Recon DL Alone.AJNR. American journal of neuroradiology · 2026
- Evaluation of a Deep Learning Reconstruction Technique for Accelerated Brain MRI Scans.Tomography (Ann Arbor, Mich.) · 2026
- Non-Contrast Fat-Saturated FLAIR MRI: Utility for Detecting Posterior and Seronegative-Associated Lesions in Optic Neuritis.Diagnostics (Basel, Switzerland) · 2026
- Deep Resolve Boost in 2D MRI for Neuroradiology: A Comparative Evaluation of Diagnostic Gains and Potential RisksAmerican Journal of Neuroradiology · 2025