Acta radiologica (Stockholm, Sweden : 1987)

Image quality evaluation of dual deep learning accelerated post-contrast Magnetization Prepared Rapid Gradient Echo (MPRAGE) imaging at 1.5 T and 3 T MRI.

Chen-Hua Chiang, Eugene Milshteyn, Mary Thomas, Dan Rettman, Susie Y Huang, Ivan Jambor

Department of Medical Imaging, Taipei Medical University Shuang Ho Hospital, Ministry of Health and Welfare, New Taipei City, Taiwan. · GE HealthCare, Boston, MA, USA.

Computational · n=50

Key points

From the paper's conclusion
  • BackgroundHigh-resolution 3D Magnetization Prepared Rapid Gradient Echo (MPRAGE) imaging is widely used in routine clinical practice; however, it can have long acquisition time.PurposeTo evaluate image quality of a new deep-learning technique, Sonic DL™ 3D (SDL), combined with older version of DL (AIR™ Recon DL, ADL) for whole brain post-contrast MPRAGE versus ADL alone at both 1.5-T and 3-T scann

Abstract

BackgroundHigh-resolution 3D Magnetization Prepared Rapid Gradient Echo (MPRAGE) imaging is widely used in routine clinical practice; however, it can have long acquisition time.PurposeTo evaluate image quality of a new deep-learning technique, Sonic DL™ 3D (SDL), combined with older version of DL (AIR™ Recon DL, ADL) for whole brain post-contrast MPRAGE versus ADL alone at both 1.5-T and 3-T scanners.Material and MethodsA total of 39 and 50 consecutive patients underwent brain MRI, including post-contrast SDL-MPRAGE (acquisition time (TA): 1 min 42 s at 1.5 T and 1 min 36 s at 3 T) and ADL-MPRAGE (TA: 2 min 21 s at 1.5 T and 2 min 15 s at 3 T) at 1.5 T and 3 T, respectively. The anonymized and randomized imaging datasets were reviewed by two neuroradiologists independently by randomized head-to-head comparison using a pre-defined 5-point scale across six categories. Interrater agreement was assessed. Non-inferiority of SDL-MPRAGE was tested using a 15% margin.ResultsInterrater agreement ranged from poor to moderate at 1.5 T (κ: -0.044 to 0.553 at 1.5 T and κ: 0.000-0.560 at 3 T). SDL-MPRAGE was non-inferior in 2/6 image quality categories at 1.5 T (GM/WM differentiation and pathological enhancement) and in 5/6 categories at 3 T (noise, GM/WM differentiation, sharpness, overall diagnostic quality, and pathological enhancement). At 3 T, SDL-MPRAGE additionally demonstrated superiority over standard MPRAGE for perceived noise category.ConclusionSDL-MPRAGE demonstrated non-inferiority in majority of the image quality categories at 3 T, potentially enabling a way for improved and more time-efficient MPRAGE acquisition.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Image quality evaluation of dual deep learning accelerated post-contrast Magnetization Prepared Rapid Gradient Echo (MPRAGE) imaging at 1.5 T and 3 T MRI — Science Skim