Image quality evaluation of dual deep learning accelerated post-contrast Magnetization Prepared Rapid Gradient Echo (MPRAGE) imaging at 1.5 T and 3 T MRI.
Chen-Hua Chiang, Eugene Milshteyn, Mary Thomas, Dan Rettman, Susie Y Huang, Ivan Jambor
Department of Medical Imaging, Taipei Medical University Shuang Ho Hospital, Ministry of Health and Welfare, New Taipei City, Taiwan. · GE HealthCare, Boston, MA, USA.
Key points
From the paper's conclusion- BackgroundHigh-resolution 3D Magnetization Prepared Rapid Gradient Echo (MPRAGE) imaging is widely used in routine clinical practice; however, it can have long acquisition time.PurposeTo evaluate image quality of a new deep-learning technique, Sonic DL™ 3D (SDL), combined with older version of DL (AIR™ Recon DL, ADL) for whole brain post-contrast MPRAGE versus ADL alone at both 1.5-T and 3-T scann
Abstract
BackgroundHigh-resolution 3D Magnetization Prepared Rapid Gradient Echo (MPRAGE) imaging is widely used in routine clinical practice; however, it can have long acquisition time.PurposeTo evaluate image quality of a new deep-learning technique, Sonic DL™ 3D (SDL), combined with older version of DL (AIR™ Recon DL, ADL) for whole brain post-contrast MPRAGE versus ADL alone at both 1.5-T and 3-T scanners.Material and MethodsA total of 39 and 50 consecutive patients underwent brain MRI, including post-contrast SDL-MPRAGE (acquisition time (TA): 1 min 42 s at 1.5 T and 1 min 36 s at 3 T) and ADL-MPRAGE (TA: 2 min 21 s at 1.5 T and 2 min 15 s at 3 T) at 1.5 T and 3 T, respectively. The anonymized and randomized imaging datasets were reviewed by two neuroradiologists independently by randomized head-to-head comparison using a pre-defined 5-point scale across six categories. Interrater agreement was assessed. Non-inferiority of SDL-MPRAGE was tested using a 15% margin.ResultsInterrater agreement ranged from poor to moderate at 1.5 T (κ: -0.044 to 0.553 at 1.5 T and κ: 0.000-0.560 at 3 T). SDL-MPRAGE was non-inferior in 2/6 image quality categories at 1.5 T (GM/WM differentiation and pathological enhancement) and in 5/6 categories at 3 T (noise, GM/WM differentiation, sharpness, overall diagnostic quality, and pathological enhancement). At 3 T, SDL-MPRAGE additionally demonstrated superiority over standard MPRAGE for perceived noise category.ConclusionSDL-MPRAGE demonstrated non-inferiority in majority of the image quality categories at 3 T, potentially enabling a way for improved and more time-efficient MPRAGE acquisition.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Deep Learning-Accelerated 3D T2 CUBE MRI of the Cochlea at 1.5T and 3T: Sonic DL With AIR Recon DL Versus AIR Recon DL Alone.AJNR. American journal of neuroradiology · 2026
- 3-dimensional gradient and spin-echo magnetic resonance cholangiopancreatography with deep learning reconstruction at 3T: Achieving superior image quality with reduced acquisition timeMagnetic Resonance Imaging · 2026
- Accelerated Renal T2-Weighted Turbo Spin-Echo Imaging with Deep Learning Reconstruction: Reduced Acquisition Time and Improved Image Quality in Patients with Renal TumorsBioengineering · 2026
- Image Quality of 1.5 T MRI Using Dual-Type Deep Learning Reconstruction for Pancreatic Cystic Lesions: An Exploratory Comparison With Conventional 3 T MRI Without Deep Learning Reconstruction.Journal of magnetic resonance imaging : JMRI · 2026
- Deep learning-accelerated contrast-enhanced 3D MRI for acute optic neuritis: faster acquisition and improved lesion conspicuity.Frontiers in neurology · 2026
- Clinical Evaluation of Deep Learning–Reconstructed Postcontrast 3D T1-Weighted Volume Interpolated Breath-Hold Examination (VIBE) Compared with Standard VIBE for Detection of Internal Auditory Canal LesionsAmerican Journal of Neuroradiology · 2026