Efficacy of balloon guide catheter in endovascular treatment according to occlusion location
Hicret Betul Adiyaman, Zehra Uysal Kocabaş, Ozlem Aykac, Atilla Ozcan Ozdemir
Key points
From the paper's conclusion- These findings support potential overall benefits of BGC use while emphasizing that location-specific effects remain unproven and require prospective evaluation.
Abstract
Background and purpose The clinical and procedural benefits of balloon guide catheter (BGC) use during mechanical thrombectomy remain debated, and whether these associations vary by occlusion location is uncertain. We evaluated the association of BGC use with thrombectomy outcomes and examined potential effect modification by occlusion location. Methods We retrospectively analyzed 475 patients with anterior-circulation large-vessel occlusion undergoing mechanical thrombectomy (BGC, n =242; non-BGC, n =233). Procedural, angiographic, and clinical outcomes were compared between groups. Multivariable logistic regression models adjusted for age, sex, baseline NIHSS, collateral status, occlusion location, atrial fibrillation, hypertension, diabetes mellitus, and coronary artery disease. BGC × occlusion-location interactions were assessed using adjusted generalized linear models. Results BGC use was independently associated with higher odds of 90-day functional independence (mRS 0–2; adjusted OR [aOR], 1.61; 95% CI, 1.05–2.48; p =0.029) and lower odds of embolization to new territory (aOR, 0.53; 95% CI, 0.35–0.81; p =0.004). BGC use was also associated with higher odds of vasospasm (aOR, 1.68; 95% CI, 1.09–2.58; p =0.018), whereas associations with first-pass recanalization and hemorrhagic complications were not significant. No significant BGC × occlusion-location interaction was observed for any evaluated outcome (all P for interaction>0.05). Conclusion BGC use was independently associated with favorable 90-day functional outcome and reduced embolization to new territory, but with increased vasospasm. No evidence of effect modification by occlusion location was identified. These findings support potential overall benefits of BGC use while emphasizing that location-specific effects remain unproven and require prospective evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Balloon guide catheter outcomes by occlusion site in the randomized PROTECT-MT trial.Journal of neurointerventional surgery · 2026
- Impact of balloon guide catheter use on procedural efficacy and early neurological outcomes in endovascular thrombectomy for anterior circulation acute ischemic stroke: a propensity-score-matched analysis.Neuroradiology · 2026
- Temporary flow arrest using EMBOGUARD™ balloon guide catheter may improve functional outcomes in acute stroke thrombectomy: a multicenter retrospective study.Frontiers in neurology · 2026
- Vascular Access Complexity and Thrombectomy Efficiency in Proximal MCA M1 Occlusion: Evaluation of the Bovine Aortic Arch-Dolichoarteriopathy Score.Medicina (Kaunas, Lithuania) · 2026
- Futile recanalisation in patients with anterior large vessel occlusion stroke randomised to mechanical thrombectomyJournal of the Neurological Sciences · 2026
- Broadway 8 system: a multicenter early evaluation of safety, performance, and clinical outcomes in mechanical thrombectomyJournal of NeuroInterventional Surgery · 2025