Broadway 8 system: a multicenter early evaluation of safety, performance, and clinical outcomes in mechanical thrombectomy
Rime Ezzeldin, Osman Mir, Adam Delora, SoHyun Boo, Santiago Ortega‐Gutiérrez, Jaydevsinh Dolia, Diogo C Haussen, Clemens M. Schirmer,
College of Central Florida · NYU Langone Health
Key points
From the paper's conclusion- The Broadway 8 system appears to be a safe and effective frontline aspiration device, demonstrating a safety and efficacy profile comparable to other large-bore aspiration systems that incorporate delivery-assist technology.
Abstract
BACKGROUND: Large-bore aspiration catheters are integral to mechanical thrombectomy (MT) for large vessel occlusions (LVOs), offering potential for improved first pass success and faster recanalization. OBJECTIVE: To assess the clinical performance, efficacy, and safety profile of the Broadway 8 system as a primary aspiration device in MT of LVOs. METHODS: This is a multicenter observational study conducted across 8 US comprehensive stroke centers. Efficacy outcomes included first pass effect (FPE), defined as a single-pass modified Treatment In Cerebral Infarction (mTICI) score ≥2c, and successful reperfusion (final mTICI ≥2b). Safety outcomes included device-related complications, symptomatic intracranial hemorrhage (sICH), and inpatient mortality. Functional outcomes included modified Rankin Scale (mRS) at discharge and delta National Institutes of Health Stroke Scale (NIHSS) score. Logistic regression was used to assess predictors of thrombus access and intermediate catheter use. RESULTS: 49 patients were included. The Broadway 8 system reached the thrombus in 44 (89.8%). Median puncture-to-thrombus and puncture-to-reperfusion times were 11 min (IQR 9-18) and 20 min (14-31), respectively. FPE was achieved in 20 (40.8%). Successful reperfusion was achieved in 46/49 (93.8%), with 35 (71.4%) using Broadway 8. sICH occurred in 2 patients (4.1%). Median mRS at discharge was 3.0 (IQR 1.0-4.0); delta NIHSS was 8 (IQR 5-12). Regression analysis showed faster reperfusion when Broadway 8 was used without an intermediate catheter. CONCLUSION: The Broadway 8 system appears to be a safe and effective frontline aspiration device, demonstrating a safety and efficacy profile comparable to other large-bore aspiration systems that incorporate delivery-assist technology.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Superlarge-Bore Versus Large-Bore Aspiration Catheters in Mechanical Thrombectomy: A Multicenter Propensity-Matched Analysis.Neurosurgery · 2026
- Superbore Aspiration Catheters: An Innovation in Mechanical Thrombectomy.Stroke (Hoboken, N.J.) · 2026
- A new era in thrombectomy: the emergence of super large bore aspiration cathetersInterdisciplinary Neurosurgery · 2025
- Optimal Catheter Size for Medium Vessel Occlusion in Aspiration Thrombectomy.Neurologia medico-chirurgica · 2026
- RESTORE: REal-world analyses of Stroke-Thrombus Occlusion REtrieval study: effectiveness, safety, and technical outcomes.Journal of neurointerventional surgery · 2026
- Thunderbolt System for acute ischemic stroke secondary to large vessel occlusion: primary results of the THUNDER study.Journal of neurointerventional surgery · 2026