科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ Journal of NeuroInterventional Surgery2025-10-02· Medicine

Broadway 8 system: a multicenter early evaluation of safety, performance, and clinical outcomes in mechanical thrombectomy

Rime Ezzeldin, Osman Mir, Adam Delora, SoHyun Boo, Santiago Ortega‐Gutiérrez, Jaydevsinh Dolia, Diogo C Haussen, Clemens M. Schirmer, Fadi Al-Saiegh, Justin Mascitelli, Ameer E Hassan, Muhammad Waqas Khan, Jan‐Karl Burkhardt, Omar Malik, Daniel Diehl, Mario Zanaty, Ahmed Aljuboori, Samantha Miller, Visish M. Srinivasan, Kyle W. Scott, Zuhair Ali, Mohamad Ezzeldin

原始摘要(英文原文)· Original abstract
BACKGROUND: Large-bore aspiration catheters are integral to mechanical thrombectomy (MT) for large vessel occlusions (LVOs), offering potential for improved first pass success and faster recanalization. OBJECTIVE: To assess the clinical performance, efficacy, and safety profile of the Broadway 8 system as a primary aspiration device in MT of LVOs. METHODS: This is a multicenter observational study conducted across 8 US comprehensive stroke centers. Efficacy outcomes included first pass effect (FPE), defined as a single-pass modified Treatment In Cerebral Infarction (mTICI) score ≥2c, and successful reperfusion (final mTICI ≥2b). Safety outcomes included device-related complications, symptomatic intracranial hemorrhage (sICH), and inpatient mortality. Functional outcomes included modified Rankin Scale (mRS) at discharge and delta National Institutes of Health Stroke Scale (NIHSS) score. Logistic regression was used to assess predictors of thrombus access and intermediate catheter use. RESULTS: 49 patients were included. The Broadway 8 system reached the thrombus in 44 (89.8%). Median puncture-to-thrombus and puncture-to-reperfusion times were 11 min (IQR 9-18) and 20 min (14-31), respectively. FPE was achieved in 20 (40.8%). Successful reperfusion was achieved in 46/49 (93.8%), with 35 (71.4%) using Broadway 8. sICH occurred in 2 patients (4.1%). Median mRS at discharge was 3.0 (IQR 1.0-4.0); delta NIHSS was 8 (IQR 5-12). Regression analysis showed faster reperfusion when Broadway 8 was used without an intermediate catheter. CONCLUSION: The Broadway 8 system appears to be a safe and effective frontline aspiration device, demonstrating a safety and efficacy profile comparable to other large-bore aspiration systems that incorporate delivery-assist technology.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Broadway 8 system: a multicenter early evaluation of safety, performance, and clinical outcomes in mechanical thrombectomy — 科研速览 Science Skim