Impact of preoperative mean keratometry on corneal higher-order aberrations and optical quality following cataract surgery.
Zhan Shen, Kaiyue Du, Bowei Yuan, Yinan Liu, Xiaoyong Chen, Jing Hong
Department of Ophthalmology, Peking University Third Hospital, Beijing, China.
Key points
From the paper's conclusion- At 3 months postoperatively, the steep group maintained higher HOAs ( p = 0.006 and 0.013), while changes from baseline were comparable among groups. iTrace analysis showed that the flat group had the lowest preoperative spherical aberration (SA) ( p = 0.003), but exhibited a significant postoperative increase in trefoil aberration compared with the regular group (mean difference, 0.10 μm; 95% CI,
Abstract
PURPOSE: To evaluate how different corneal meridian characteristics influence visual outcomes, surgically induced astigmatism (SIA), and higher-order aberrations (HOAs) following phacoemulsification with intraocular lens implantation in cataract patients. METHODS: Patients were divided into three groups according to preoperative mean keratometry (Kmean): flat (≤ 43.0 D), regular (43.0-46.0 D), and steep (≥ 46.0 D). Outcomes included corrected distance visual acuity (CDVA), anterior and posterior corneal astigmatism, SIA measured with the Pentacam, and HOAs assessed using both Pentacam and iTrace at 1 and 3 months postoperatively. RESULTS: CDVA, corneal astigmatism, and SIA parameters showed no significant between-group differences (all p > 0.05), with the primary clinically relevant differences lying in intrinsic HOAs and aberration changes. Preoperatively, Pentacam measurements revealed that the steep group had significantly higher anterior and posterior corneal HOAs than the flat group (p = 0.006 and <0.001, respectively). At 3 months postoperatively, the steep group maintained higher HOAs (p = 0.006 and 0.013), while changes from baseline were comparable among groups. iTrace analysis showed that the flat group had the lowest preoperative spherical aberration (SA) (p = 0.003), but exhibited a significant postoperative increase in trefoil aberration compared with the regular group (mean difference, 0.10 μm; 95% CI, 0.02 to 0.18; Padj=0.042), alongside a non-significant trend toward higher SA. CONCLUSION: Cataract surgery provides effective and consistent refractive and visual outcomes in eyes across different Kmean profiles. Steeper corneas consistently show higher intrinsic HOAs, whereas flatter corneas demonstrate a statistically significant increase in trefoil and a non-significant trend toward higher SA compared with regular corneas.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of steep-axis incisions on anterior and posterior corneal astigmatism and higher-order aberrations after cataract surgery.Frontiers in medicine · 2026
- Characteristics of Posterior Corneal Astigmatism in 28,551 Chinese Eyes with Cataracts.Journal of clinical medicine · 2026
- Preoperative Keratometric Power as the Primary Biometric Determinant of Thirty-Day Visual Rehabilitation Following Phacoemulsification: A Retrospective Cohort Study in West Sumatra, IndonesiaOpen Access Indonesian Journal of Medical Reviews · 2026
- Clinical Interchangeability Boundaries of Pentacam AXL WAVE in Preoperative Biometry for Cataract Surgery: An Agreement Study with IOLMaster 700 and Pentacam.Journal of clinical medicine · 2026
- Systematic Differences in Corneal Curvature and Power Measurements Between the IOLMaster 700 and the Anterion and Mapping Strategies for Cross-Device Use.Diagnostics (Basel, Switzerland) · 2026
- Agreement of keratometry measurements for toric IOL planning in routine clinical practice: KR-800, IOLMaster 500, and Pentacam HR.PloS one · 2026