Friction and interfacial mechanics of surgical suturing: needle–tissue penetration, suture drag and friction-control strategies
Shubham Gupta, Varatharajan Prasannavenkadesan
Key points
From the paper's conclusion- Future progress will depend on standardised wet-tissue testing, clearer separation of force components, repeated-passage evaluation of coatings, tissue-specific needle–suture selection, and stronger links between mechanical measurements, tissue response and adaptive robotic control.
Abstract
Surgical suturing involves a sequence of tribological contacts that begins with needle penetration, continues through suture pull-through, and culminates in knot tightening and locking. Uncontrolled friction at these interfaces can cause tissue trauma, coating delamination, or knot slippage. This narrative review synthesises the biomechanics and tribology of the needle–tissue, suture–tissue, and suture–suture interfaces. PubMed, Scopus and Web of Science were searched for studies published from January 2000 to July 2026, and studies were selected for mechanical relevance and synthesised by tribological interface. Needle insertion force is a combined response of tissue deformation, cutting and shaft friction, with attention to needle geometry, trajectory, velocity, tissue properties and force sensing. Suture drag is examined in relation to material, diameter, surface roughness, monofilament or multifilament construction, hydration, loading and pulling speed. Surface-engineering approaches, including lubricants, silicone and polymeric treatments, antimicrobial coatings, dopamine-, chitosan- and graphene-based modifications, and tissue-integrating sutures, are evaluated for friction reduction, durability, handling and knot performance. The review also discusses the transition from low resistance during passage to sufficient suture–suture friction after tightening, together with experimental apparatus, biological tissue models, finite-element methods and robotic force feedback. Evidence shows that friction is stage-dependent and should be controlled rather than uniformly minimised. Future progress will depend on standardised wet-tissue testing, clearer separation of force components, repeated-passage evaluation of coatings, tissue-specific needle–suture selection, and stronger links between mechanical measurements, tissue response and adaptive robotic control.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bio-inspired electrosurgical knife with lubricant-assisted porous-groove surface and micro-serrated edge for reducing tissue adhesion and thermal injury.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026
- When Bioinspiration Doesn't Help: Mechanical Behavior of Bio-inspired Curved Needles During Curvilinear Insertion.Biomedical physics & engineering express · 2026
- Passivity-Preserving Smoothing of Force Discontinuities at Tissue Boundaries in Haptic Surgical SimulationApplied Sciences · 2026
- Advanced surface lubrication modifications for medical catheters: Materials, strategies, and evaluation.Advances in colloid and interface science · 2026
- Practical Suture Techniques for Drain Securement: A Comparative Overview.Techniques in vascular and interventional radiology · 2026
- Biodegradable piezoelectric suture for real-time biomechanical sensing and therapeutic intervention.Science bulletin · 2026