Field monitoring study of reaction walls and pedestals during construction and service phases
Haoran Wang, Qikeng Xu, Yongang Ding, Pengyue Hu, Shiju Ma, Qiang Liu
Key points
From the paper's conclusion- This study presents a full-scale field monitoring investigation of a prestressed reaction wall and pedestal system throughout both construction and service phases using an integrated network of vibrating-wire and fiber-optic strain sensors.
Abstract
This study presents a full-scale field monitoring investigation of a prestressed reaction wall and pedestal system throughout both construction and service phases using an integrated network of vibrating-wire and fiber-optic strain sensors. The monitoring program captures the evolution of concrete microstrain and reinforcement stress under hydration, prestressing, and quasi-static service loading conditions. During construction, tendon tensioning induced a redistribution of internal strain and stress, with the maximum concrete compressive strain increasing from −168.37 με before tensioning to −290.90 με after tensioning, accompanied by an increase in reinforcement compressive stress. During subsequent quasi-static loading, the maximum concrete compressive strain reached −321.36 με, corresponding to approximately 54% of the design strain limit, while the maximum reinforcement stress remained below 25% of the design strength. All monitoring locations remained under compression throughout the monitored stages, indicating stable overall mechanical behavior of the prestressed system. Comparative evaluation of the sensing methods indicates that fiber-optic sensors are effective in capturing localized strain anomalies associated with cracking, whereas vibrating-wire sensors provide stable measurements for long-term response tracking. The findings provide full-scale experimental evidence for understanding the relationship between construction-induced stress states and subsequent service performance of mass concrete prestressed structures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Stress Monitoring of a Curved Prestressed Shear Wall in a Fusion Energy Experimental FacilityEngineering Research Express · 2026
- Experimental Investigation of Position-Dependent Prestress Transfer in Series-Produced Bridge Approach Slabs on a Long-Line Pretensioning BedBuildings · 2026
- Monitoring the Shear Behavior of Reinforced Concrete Beams Using Fiber Optic Sensors Installed in the Compression Zone.Sensors (Basel, Switzerland) · 2026
- Mechanical Response and Deformation Evolution of Composite Linings with Prefabricated Inverts in Mining-Method Tunnels During ConstructionBuildings · 2026
- Application of Numerical Methods for Monitoring the Technical Condition of Cable Post-Tensioned Concrete Girders and Their Constituent Materials.Materials (Basel, Switzerland) · 2026
- Comparison of strain measurement methods for monitoring residual stress build-up in prestressed fiber-reinforced polymer concreteThe International Journal of Advanced Manufacturing Technology · 2026