Comparison of strain measurement methods for monitoring residual stress build-up in prestressed fiber-reinforced polymer concrete
Michelle Engert, Daniel Christopher Bozó, Larissa Born, Götz T. Gresser, Hans-Christian Möhring
Key points
From the paper's conclusion- The findings indicated no consistent influence of the curing temperature on the abrupt change in elongation, whereas the first eigen frequency showed temperature-dependent trends that varied with the time of prestressing force release and require further validation.
Abstract
Prestressed fiber-reinforced polymer concrete (PFRPC) facilitates the substitution of conventional steel structural elements in machine tools with vibration-damping lightweight components. While these components offer superior machining results, they demonstrate deficiencies regarding static stiffness. The design of such structures is rather complex due to the diverging material properties and a residual stress field. This challenge requires a fundamental understanding of how the residual stress field within the material affects its mechanical properties. To achieve this objective, it is imperative to conduct a detailed characterization of the residual stress field that is induced by the integration of the prestressed carbon fiber rovings. The experimental findings revealed that the residual stress field is formed in particular by a characteristic, abrupt change in elongation at the instant when the prestressing force is released. Subsequently, the measurement methodology was employed to quantify the influence of temperature during the curing process and the instant of release of the prestressing force on the residual stress field. The findings indicated no consistent influence of the curing temperature on the abrupt change in elongation, whereas the first eigen frequency showed temperature-dependent trends that varied with the time of prestressing force release and require further validation. However, it was observed that a release of the prestressing force after 22 h, as opposed to 24 h as previously studied, resulted in an enhancement of up to 25% in the abrupt change in elongation. However, these samples showed a reduced first eigen frequency, which indicates a reduction in stiffness. This apparent contradiction is attributed to the fact that the Young’s modulus of epoxy resin increases with the curing time. For future sample production, a release of the prestressing force after 24 h is advised. Based on the exploratory results, the curing temperature should be set to at least 22 °C.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- 3D meso-scale finite element analysis of FRP-confined concreteJournal of Asian Concrete Federation · 2026
- In-Service Performance Deterioration Analysis of FRP-Reinforced Concrete Structures Exposed to Natural Marine Environments: A Theoretical Approach and ApplicationJournal of Composites for Construction · 2025
- Progressive monitoring of temperature and stress induced damages in fiber-reinforced cementitious composites through electrical admittance response of coupled piezoelectric sensorsMechanics of Advanced Materials and Structures · 2026
- Influence of Water Exposure on the Relaxation Behaviour of Short Fibre Reinforced Polycarbonate.Polymers · 2026
- Field monitoring study of reaction walls and pedestals during construction and service phasesFrontiers in Materials · 2026
- Durability of Fiber-Reinforced Polymer Composites in Harsh Civil Infrastructure Environments: Mechanisms, Prediction and Design.Polymers · 2026