Single-image performance alone does not establish longitudinal technical performance: a paired-error framework for artificial intelligence-enabled quantitative imaging
Hunter Colson, Manuel Valdebran
Key points
From the paper's conclusion- The numerical effects depend on the synthetic targets and acquisition conditions and do not establish clinical performance.
Abstract
Introduction Artificial intelligence (AI)-enabled imaging systems are often evaluated on individual images, although many applications require accurate measurement of change across visits. Errors that persist across visits can cancel when measurements are subtracted; errors that vary can create apparent change. Methods We combine established measurement principles in a framework that evaluates error in measured change, the proportion of cases yielding both measurements (pair availability), and the acquisition and processing conditions tested. Two synthetic lesion-area experiments used exact reference geometry. The repeated-camera experiment used 72 lesions divided between no change and 10% area growth, with 960 combinations of acquisition and processing settings per arm using at least one trained AI model. The acquisition-resampling experiment varied camera pose, distance, and illumination between visits for the same 36 unchanged lesions. Results Repeating camera and lighting conditions favored similar errors across visits: assuming independent errors overestimated no-change paired-error standard deviation (SD) by a median factor of 6.4. In the no-change arm, rankings by pooled single-image error SD and paired-change error SD were correlated (Spearman correlation, 0.724), but reversed in 23.2% of unequal comparisons. Reversals occurred in 23.8% of comparisons with a 1.5-2-fold single-image SD advantage and 13.8% with a 2-3-fold advantage; nearly tied rankings were unstable when lesions were resampled. In the repeated-camera experiment, both measurements were obtained for 95.3% of 8,640 scheduled pairs; all final failures arose at marker detection. Compared with matched acquisition, acquisition resampling increased paired-change error SD in all 48 configurations using a trained AI model, by a median factor of 6.2, while single-image error SD changed much less. Discussion These findings support evaluating change error and measurement failures directly. The numerical effects depend on the synthetic targets and acquisition conditions and do not establish clinical performance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Performance uncertainty in medical image analysis: A large-scale investigation of confidence intervals.Medical image analysis · 2026
- AI output and image quality: reducing avoidable recalls in breast screeningEuropean Journal of Public Health · 2026
- Clinical Validation and Continuous Monitoring of Artificial Intelligence in Medical Imaging: Lessons from Platform-Based Deployment.The Indian journal of radiology & imaging · 2026
- Fairness Evaluation for Diffusion and Flow Models Should Account for the Generation Path: Implications for Clinical ImagingarXiv · 2026
- Deployer-side governance of medical imaging artificial intelligence: the regulatory readiness instrument (RRI-MI) for multi-jurisdictional and post-market compliance.International journal of medical informatics · 2026
- Deep Learning Quality Control for RECIST-Oriented Assessment: A Vision Transformer Predicts Inter-Reader Variability of Unidimensional Lesion Measurements on Contrast CT.Cancers · 2026