Performance uncertainty in medical image analysis: A large-scale investigation of confidence intervals.
Pascaline André, Charles Heitz, Evangelia Christodoulou, Annika Reinke, Carole H Sudre, Michela Antonelli, Patrick Godau, M Jorge Cardoso,
Sorbonne Université, Institut du Cerveau - Paris Brain Institute - ICM, CNRS, Inria, Inserm, AP-HP, Hôpital de la Pitié-Salpêtrière, F-75013, Paris, France. Electronic address: pascaline.a0307@gmail.com. · Sorbonne Université, Institut du Cerveau - Paris Brain Institute - ICM, CNRS, Inria, Inserm, AP-HP, Hôpital de la Pitié-Salpêtrière, F-75013, Paris, France. Electronic address: charles.heitz1308@gmail.com.
Key points
From the paper's conclusion- Our analysis revealed five principal findings: (1) the sample size required for reliable CIs varies from a few dozens to several thousands of cases depending on study parameters; (2) CI behavior is strongly affected by the choice of performance metric; (3) aggregation strategy substantially influences the reliability of CIs, e.g. they require more observations for macro than for micro; (4) the mac
Abstract
Performance uncertainty quantification is essential for reliable validation and eventual clinical translation of medical imaging artificial intelligence (AI). Confidence intervals (CIs) play a central role in this process by indicating how precise a reported performance estimate is. Yet, due to the limited amount of work examining CI behavior in medical imaging, the community remains largely unaware of how many diverse CI methods exist and how they behave in specific settings. The purpose of this study is to close this gap. To this end, we conducted a large-scale empirical analysis across a total of 24 segmentation and classification tasks, using 19 trained models per task group, a broad spectrum of commonly used performance metrics, multiple aggregation strategies, and several widely adopted CI methods. Reliability (coverage) and precision (width) of each CI method were estimated across all settings to characterize their dependence on study characteristics. Our analysis revealed five principal findings: (1) the sample size required for reliable CIs varies from a few dozens to several thousands of cases depending on study parameters; (2) CI behavior is strongly affected by the choice of performance metric; (3) aggregation strategy substantially influences the reliability of CIs, e.g. they require more observations for macro than for micro; (4) the machine learning problem (segmentation versus classification) modulates these effects; (5) different CI methods are not equally reliable and precise depending on the use case. Finally, we derived practical implications of this study in the form of a decision tree which shall prove useful to the community. This paves the way for future consensus guidelines on reporting performance uncertainty.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A unified medical image segmentation evaluation method combining multi-metrics and confidence.Medical & biological engineering & computing · 2026
- Average Calibration Losses for Reliable Uncertainty in Medical Image SegmentationIEEE Transactions on Medical Imaging · 2026
- Segmentation Confidence for Arbitrary CNNsarXiv · 2026
- Artificial intelligence (AI) imaging models optimization: From pre-processing to validationEuropean Journal of Radiology Artificial Intelligence · 2026
- Single-image performance alone does not establish longitudinal technical performance: a paired-error framework for artificial intelligence-enabled quantitative imagingFrontiers in Imaging · 2026
- Segmenting with confidence through uncertainty quantification for brain tumor imagingnpj Digital Medicine · 2026