Deep Learning Quality Control for RECIST-Oriented Assessment: A Vision Transformer Predicts Inter-Reader Variability of Unidimensional Lesion Measurements on Contrast CT.

Abdalla Ibrahim, Amer Hammad, Lucy Wang, Hao Yang, Lawrence H Schwartz, Binsheng Zhao

Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Ave, New York, NY 10065, USA. · The D-Lab, Department of Precision Medicine, GROW-Research Institute for Oncology and Reproduction, Maastricht University, Universiteitsingel 40, 6229 ER Maastricht, The Netherlands.

Computational · n=280

Key points

From the paper's conclusion
  • Background/Objectives: Inter-reader variation can alter unidimensional tumor measurements used in RECIST-oriented response assessment.

Abstract

Background/Objectives: Inter-reader variation can alter unidimensional tumor measurements used in RECIST-oriented response assessment. Unlike systems that automate segmentation or target selection, this study aimed to predict lesion-specific measurement uncertainty itself. Methods: The development cohort comprised 463 lung, liver, and lymph-node lesions from 280 patients in Vol-PACT, with four segmentations per lesion. Inter-reader variability was defined as (maximum longest diameter-minimum longest diameter)/minimum longest diameter. A Swin Transformer was trained to regress this continuous score. A value > 0.20 was used as a pragmatic high-variability alert threshold, with high variability designated as the positive class; this threshold is not equivalent to RECIST progressive disease. Preliminary external evaluation used 21 NSCLC lesions with five reader contours, providing one reader mask at a time. Results: The validation and internal test AUCs were 0.74 (95% CI, 0.61-0.85) and 0.89 (95% CI, 0.80-0.95), respectively. On the internal test set, MAE was 0.10 (95% CI, 0.08-0.12), accuracy was 82% (95% CI, 74-90%), sensitivity 72% (95% CI, 59-85%), and specificity for lower-variability lesions was 92% (95% CI, 82-100%). Across the five external readers, AUCs ranged from 0.77 to 0.92; the wide confidence intervals reflect the small external sample. Conclusions: This proof-of-concept model may provide a measurement-quality signal that supports target selection or adjudication. Larger multi-institutional studies, patient-level resampling, calibration, ablation testing, and workflow validation are required before clinical use.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers