Deep Learning Quality Control for RECIST-Oriented Assessment: A Vision Transformer Predicts Inter-Reader Variability of Unidimensional Lesion Measurements on Contrast CT.
Abdalla Ibrahim, Amer Hammad, Lucy Wang, Hao Yang, Lawrence H Schwartz, Binsheng Zhao
Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Ave, New York, NY 10065, USA. · The D-Lab, Department of Precision Medicine, GROW-Research Institute for Oncology and Reproduction, Maastricht University, Universiteitsingel 40, 6229 ER Maastricht, The Netherlands.
Key points
From the paper's conclusion- Background/Objectives: Inter-reader variation can alter unidimensional tumor measurements used in RECIST-oriented response assessment.
Abstract
Background/Objectives: Inter-reader variation can alter unidimensional tumor measurements used in RECIST-oriented response assessment. Unlike systems that automate segmentation or target selection, this study aimed to predict lesion-specific measurement uncertainty itself. Methods: The development cohort comprised 463 lung, liver, and lymph-node lesions from 280 patients in Vol-PACT, with four segmentations per lesion. Inter-reader variability was defined as (maximum longest diameter-minimum longest diameter)/minimum longest diameter. A Swin Transformer was trained to regress this continuous score. A value > 0.20 was used as a pragmatic high-variability alert threshold, with high variability designated as the positive class; this threshold is not equivalent to RECIST progressive disease. Preliminary external evaluation used 21 NSCLC lesions with five reader contours, providing one reader mask at a time. Results: The validation and internal test AUCs were 0.74 (95% CI, 0.61-0.85) and 0.89 (95% CI, 0.80-0.95), respectively. On the internal test set, MAE was 0.10 (95% CI, 0.08-0.12), accuracy was 82% (95% CI, 74-90%), sensitivity 72% (95% CI, 59-85%), and specificity for lower-variability lesions was 92% (95% CI, 82-100%). Across the five external readers, AUCs ranged from 0.77 to 0.92; the wide confidence intervals reflect the small external sample. Conclusions: This proof-of-concept model may provide a measurement-quality signal that supports target selection or adjudication. Larger multi-institutional studies, patient-level resampling, calibration, ablation testing, and workflow validation are required before clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multicenter AI- versus expert-assisted RECIST target lesion measurements in follow-up body CT of patients with cancer.Radiology advances · 2026
- Uncertainty-Aware Multiscale Treatment Response Forecasting in Advanced Non-Small Cell Lung Cancer Using Residual-Variance Conformal Prediction.medRxiv : the preprint server for health sciences · 2026
- Evaluating the Effects of Inter-Observer and Model Variability on Radiological Peritoneal Cancer Index AssessmentarXiv · 2026
- SYNAPSE-X: a calibration-aware vision transformer framework for selective referral in multi-class brain tumor MRI classificationNeural Computing and Applications · 2026
- The Performance Ceiling of LIDC-IDRI Is Label-Defined Rather than Image-Defined: A Computable Bound and a Purposive Audit of Published Studies.Journal of imaging informatics in medicine · 2026
- Clinical selectivity and failure modes of automated chest radiograph report evaluation metrics: a cross-dataset analysis of ReXErr-v1 and RadEvalXmedRxiv · 2026