Experience-dependent integration of a commercial AI system with C-TIRADS for thyroid nodule assessment: a retrospective single-center study.
Jian Ding, Minjie Li, Yingxia Zhang
Department of Ultrasound, Zhalantun People's Hospital, Hulunbuir, China. · Department of Ultrasound, Affiliated Hospital of Inner Mongolia Medical University, Hohhot, China.
Key points
From the paper's conclusion- In this retrospective single-center, pathology-enriched cohort, the effect of AI-assisted C-TIRADS adjustment appeared to vary by sonographer experience. Mandatory adjustment may be more helpful for junior sonographers, whereas flexible integration may be more useful for senior sonographers. These findings should be interpreted as preliminary workflow observations and require validation in larger prospective multicenter studies.
Abstract
OBJECTIVE: To evaluate the diagnostic performance of a commercial AI-assisted ultrasound system and C-TIRADS-based assessment among sonographers with different levels of experience, and to explore how two AI-assisted adjustment strategies performed in a retrospective clinical workflow for thyroid nodule evaluation. METHODS: This retrospective single-center study included adult patients with thyroid nodules who underwent conventional ultrasonography and commercial AI-assisted analysis at our hospital between December 2022 and December 2023 and had available reference-standard outcomes. Three senior and three junior sonographers independently reviewed stored ultrasound images and videos and reached group-consensus C-TIRADS classifications while blinded to AI results and final diagnoses. Two AI-assisted integration strategies were evaluated: Strategy 1 required a one-level adjustment of the initial C-TIRADS category according to AI output, whereas Strategy 2 allowed flexible reconsideration after review of the AI result. Surgical histopathology or cytological results with follow-up-supported benign classification were used as reference standards. Diagnostic performance, agreement with reference standards, and biopsy-related indicators were compared across approaches. RESULTS: A total of 389 thyroid nodules from 343 patients were included. Because the cohort required cytological or pathological confirmation and complete imaging data, the study population was enriched for malignancy (58.10%). The AI system showed higher sensitivity and accuracy than the junior sonographer group and comparable performance to the senior sonographer group. Among senior sonographers, the flexible strategy was associated with improvements in sensitivity, accuracy, negative predictive value, agreement, and AUC, whereas the mandatory strategy did not yield significant overall benefit. Among junior sonographers, the mandatory strategy was associated with improvements in sensitivity, accuracy, negative predictive value, agreement, and AUC, whereas the flexible strategy showed limited benefit. In this selected cohort, the more favorable strategy for each experience group was also associated with lower unnecessary biopsy rates and higher positive biopsy yields, without a significant increase in missed diagnoses. CONCLUSION: In this retrospective single-center, pathology-enriched cohort, the effect of AI-assisted C-TIRADS adjustment appeared to vary by sonographer experience. Mandatory adjustment may be more helpful for junior sonographers, whereas flexible integration may be more useful for senior sonographers. These findings should be interpreted as preliminary workflow observations and require validation in larger prospective multicenter studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic performance and clinical integration of an artificial intelligence-assisted ultrasound decision support tool for thyroid nodules at a tertiary cancer centre.Ultrasound (Leeds, England) · 2026
- Investigation of S-Detect AI (a computer-aided diagnosis tool) versus ultrasound operators for thyroid nodule classification using British Thyroid Association guidelines: A pilot diagnostic accuracy study.Ultrasound (Leeds, England) · 2026
- Artificial Intelligence-Assisted ACR TI-RADS Assessment of Thyroid Nodules: Potential for Reducing Unnecessary Biopsies in a Prospective Single-Center Study.Tomography (Ann Arbor, Mich.) · 2026
- Artificial Intelligence-Assisted ACR TI-RADS and Bethesda-like Risk Prediction for Indeterminate Thyroid Nodules: A Retrospective Proof-of-Concept Evaluation.Diagnostics (Basel, Switzerland) · 2026
- Real-Time AI-Based ACR TI-RADS Classification of Thyroid Nodules on the Ultrasound Console: A Prospective Agreement Study in a Region with Historical Iodine Deficiency.Diagnostics (Basel, Switzerland) · 2026
- Artificial intelligence-based systems as auxiliary tools for thyroid nodule malignancy detection on ultrasound: a systematic review and meta-analysis of diagnostic accuracy.Gland surgery · 2026