Artificial Intelligence-Assisted ACR TI-RADS and Bethesda-like Risk Prediction for Indeterminate Thyroid Nodules: A Retrospective Proof-of-Concept Evaluation.
Duzgun Yildirim, Deniz Esin Tekcan Sanli, Meltem Kursun, Burcu Bektas Gunes, Aytug Altundag, Leonardo Obinna Iheme, Mustafa Hurmuzli, Ahmet Necati Sanli,
Department of Radiology, Acıbadem Taksim Hospital, Istanbul 34373, Turkey. · Department of Radiology, Faculty of Medicine, Gaziantep University, Gaziantep 27310, Turkey.
Key points
From the paper's conclusion- We evaluated the TRAICK (version 1.9.4; TRAICK, Istanbul, Türkiye) artificial intelligence (AI) system, which generates an American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) category and an imaging-derived Bethesda-like risk category from gray-scale ultrasound images.
Abstract
Background/Objectives: Cytologically indeterminate thyroid nodules (Bethesda III-IV) remain a diagnostic challenge. We evaluated the TRAICK (version 1.9.4; TRAICK, Istanbul, Türkiye) artificial intelligence (AI) system, which generates an American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) category and an imaging-derived Bethesda-like risk category from gray-scale ultrasound images. Methods: This retrospective proof-of-concept study included 52 surgically resected nodules with Bethesda III (n = 29) or IV (n = 23) cytology, with histopathology of the index nodule as the reference standard. The two TRAICK outputs were analyzed separately, and the ACR TI-RADS output was compared with two radiologists using the McNemar and DeLong tests. Results: Twenty-three nodules (44.2%) were malignant on index-nodule histopathology. The TRAICK ACR TI-RADS output had an accuracy of 71.2% (95% CI 57.7-81.7) and an area under the ROC curve (AUC) of 0.762 (0.640-0.884). Its AUC did not differ significantly from that of Radiologist 1 (0.762 vs. 0.777, p = 0.783); specificity was higher (65.5% vs. 37.9%, p = 0.021), whereas sensitivity was lower without a statistically significant difference (78.3% vs. 91.3%, p = 0.250). Compared with Radiologist 2, the TRAICK ACR TI-RADS output had higher accuracy (71.2% vs. 51.9%, p = 0.013), specificity (65.5% vs. 24.1%, p < 0.001), and AUC (0.762 vs. 0.629, p = 0.042). The Bethesda-like output had an AUC of 0.822 (0.707-0.938), with a sensitivity of 60.9% and specificity of 86.2% at the V-VI threshold. In sensitivity analyses, the AUC of the ACR TI-RADS output did not differ significantly from that of Radiologist 1, whereas its AUC advantage over Radiologist 2 was not statistically significant when low-risk neoplasms were classified as malignant. Conclusions: In this small, selected surgical cohort, the TRAICK ACR TI-RADS output showed discrimination that did not differ significantly from that of the more accurate of two experienced radiologists, with higher specificity, and its Bethesda-like output showed promising discrimination. These findings support further study of TRAICK as a complementary aid for preoperative decision-making; independent prospective validation is needed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial Intelligence-Assisted ACR TI-RADS Assessment of Thyroid Nodules: Potential for Reducing Unnecessary Biopsies in a Prospective Single-Center Study.Tomography (Ann Arbor, Mich.) · 2026
- Real-Time AI-Based ACR TI-RADS Classification of Thyroid Nodules on the Ultrasound Console: A Prospective Agreement Study in a Region with Historical Iodine Deficiency.Diagnostics (Basel, Switzerland) · 2026
- Artificial intelligence-assisted risk stratification of thyroid nodules with atypia of undetermined significanceEuropean Thyroid Journal · 2026
- Artificial intelligence-based systems as auxiliary tools for thyroid nodule malignancy detection on ultrasound: a systematic review and meta-analysis of diagnostic accuracy.Gland surgery · 2026
- Clinical value of artificial intelligence ultrasound-assisted diagnostic system in the differential diagnosis of benign and malignant thyroid nodules: A retrospective case-control study.Medicine · 2026
- Artificial intelligence in thyroid ultrasound: clinical applications and perspectives.Frontiers in endocrinology · 2026