Electric field effects of pulsed field ablation through adjacent non-cardiac tissues in an in vitro hybrid model.
Denis Fedorov, Laura Dippel, Jan Minners, Johannes Steinfurt, Julian Mueller, Dirk Westermann, Heiko Lehrmann, Thomas Arentz,
Department of Cardiology and Angiology, University Heart Center Freiburg/Bad Krozingen, Medical Center, University of Freiburg, Bad Krozingen, Germany.
Key points
From the paper's conclusion- Our findings show that measurable electroporation effects can be produced in a hybrid potato model beyond ex vivo non-cardiac tissues, with tissue-dependent differences in lesion depth and lesion area.
Abstract
BACKGROUND: Endocardial ablation of atrial arrhythmias may occasionally produce insufficient lesion depth. Pulsed-field ablation (PFA) may generate measurable electroporation effects beyond interposed non-cardiac tissues, but field propagation across such tissues remains poorly understood. METHODS: We introduced an in vitro model to visualize electroporation in potato slices overlaid by ex vivo porcine tissues, including esophagus, aortic root, and pulmonary trunk. A control group received PFA without any barrier. Lesions were created using a commercially available multielectrode PFA catheter across three subsets using different numbers of applications. Depth of irreversible electroporation, total lesion depth (irreversible and reversible electroporation), and irreversible electroporation surface area were quantified. RESULTS: Across 60 lesions, two-way ANOVA showed significant effects of barrier tissue and number of applications on all primary endpoints (all p < 0.001). A significant tissue-by-dose interaction was observed only for total lesion depth (p < 0.001). Compared with control, irreversible electroporation depth was lower beneath the esophageal, aortic root, and pulmonary trunk by 2.01, 2.21, and 1.44 mm, respectively. Total lesion depth was unchanged beneath the esophagus but lower beneath the aorta and pulmonary trunk. Irreversible electroporation area was greater beneath the esophagus, lower beneath the aorta, and unchanged beneath the pulmonary trunk. CONCLUSION: Our findings show that measurable electroporation effects can be produced in a hybrid potato model beyond ex vivo non-cardiac tissues, with tissue-dependent differences in lesion depth and lesion area.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development and validation of a contact force-independent index for predicting pulsed field ablation lesion depthEuropean Heart Journal · 2026
- Acoustic effects during pulsed field ablation: measurement and control of bubble and void formation.Journal of colloid and interface science · 2026
- Specific effects of Pulsed Field Ablation on the cardiac tissue, the nervous system and the conduction system in experimental and clinical studies.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
- Controlling pulsed field ablation efficacy during ablation procedures.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
- Biophysical principles of pulsed field ablation.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
- Thermal preconditioning of targeted tissue enhances pulsed field ablation lesionsJournal of Interventional Cardiac Electrophysiology · 2026