European Heart Journal

Development and validation of a contact force-independent index for predicting pulsed field ablation lesion depth

B Ren, R Zeng, W Li, X Hu, F Li, A Gong, Y Cao, Y Huang,

Key points

From the paper's conclusion
  • We performed the procedure using a 7-electrode circular PFA system in animal experiments.

Abstract

Background The lesion depth prediction index has been demonstrated to optimize radiofrequency ablation strategies. Pulsed field ablation (PFA) similarly requires real-time prediction of lesion depth to balance ablation dosage. Currently, most PFA prediction indices rely on contact force. However, contact force-based lesion depth prediction is difficult to integrate into multi-electrode catheters with complex shapes, which represent the current mainstream design for PFA catheters. Purpose This study developed and validated a contact force-independent PFA index and assessed its reliability. Methods A 3D electric field model was constructed. An impedance-based tissue-proximity index served as a substitute for contact force to evaluate electrode–tissue contact. The predictive model incorporated the tissue-proximity index, number of pulse applications, and voltage. We performed the procedure using a 7-electrode circular PFA system in animal experiments. In six pigs, we injected 250 mL of 1% triphenyl tetrazolium chloride 2 hours post-ablation for staining. Following euthanasia, we excised the hearts, measured lesion depth, and submitted samples for pathological examination. Prediction accuracy was evaluated using the R-value, root mean square error (RMSE), and mean absolute error (MAE). Results Computer modeling incorporated real-time impedance variation, voltage, and number of applications to initially establish the algorithm. In the acute phase of animal experiments, both the number of applications (R=0.474, p<0.001) and the tissue proximity indication (R=0.516, p<0.001) were positively correlated with lesion depth. The final integrated model achieved 84.0% accuracy within 1.0 mm (R=0.74, RMSE=0.68 mm, MAE=0.56 mm) (Panel A). Histological and pathological examinations confirmed these lesions (Panel B–C). Conclusion The DPI effectively predicts lesion depth without requiring contact force. This provides proof of feasibility for impedance-based prediction of PFA lesion depth and offers valuable inspiration for the future development of predictive algorithms.Panel

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers