Finite element evaluation of a novel adjustable-length partial ossicular replacement prosthesis.
Qingsong Liu, Xiao Qin, Songbo Xue, Zhiqiang Gao, Guodong Feng
Department of Otolaryngology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China. · Department of Skull Base Surgery Center, Huanhu Hospital Affiliated to Tianjin Medical University, Tianjin, China.
Key points
From the paper's conclusion- These findings warrant further experimental validation using physical middle ear models and animal studies to assess long-term safety and functional outcomes.
Abstract
PURPOSE: Partial ossicular replacement prosthesis (PORP) reconstruction is a standard otologic procedure for restoring sound conduction in patients with conductive hearing loss resulting from partial ossicular chain disruption. Current commercial PORP designs exhibit several limitations that may affect long-term hearing outcomes and contribute to complication risks. This study presents a novel adjustable-length PORP and systematically evaluates its biomechanical performance and sound transmission fidelity using a finite element analysis (FEA) framework, thereby providing computational evidence for preclinical feasibility evaluation. METHODS: The proposed prosthesis incorporates a deformable bent titanium alloy connecting rod sandwiched between two polyetheretherketone (PEEK) coupling components: a tympanic-side circular disc and a stapes-head bowl. The connecting rod incorporates three independently adjustable bend angles (α, β, γ) that enable intraoperative alignment optimization. An FEA model of the intact human middle ear was constructed, and baseline vibratory transmission characteristics were quantified using the stapes footplate frequency response curve. An FEA model of the middle ear reconstructed with the novel adjustable-length PORP was then generated, and vibratory conduction performance was quantified across continuous length settings spanning 2.3-3.5 mm. RESULTS: Across the evaluated length range of 2.4-3.5 mm, the prosthesis demonstrates consistent stapes footplate velocity transmission, with predicted hearing loss remaining below 17 dB across the 100 Hz-10 kHz frequency range. Adjusting the prosthesis to the minimum 2.3 mm length increased maximum hearing loss to 34 dB, consistent with structural overcompression. CONCLUSION: This finite element analysis provides computational evidence which suggesting the preclinical biomechanical feasibility of the proposed adjustable-length PORP for ossicular chain reconstruction. The predicted results suggest potentially acceptable sound transmission performance and favorable mechanical conditions at the prosthesis-bone interfaces. These findings warrant further experimental validation using physical middle ear models and animal studies to assess long-term safety and functional outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical Assessment of a Novel Self-Ligating Orthodontic Bracket Using Finite Element Analysis: The LUMACA System.Dentistry journal · 2026
- 3D finite element coupling - lumped model of the ear for the study of the acoustic attenuation of earplugsPhysica Scripta · 2026
- A Preclinical Approach to 3D-Printed Osseointegration Prosthesis: Improving Functional Outcomes and Reducing Complications in Residual Limb Reconstruction.Annals of biomedical engineering · 2026
- Modular Cage-Type Prosthetic Construction for Lumbar Intervertebral Reconstruction: A Computer-Aided Design-Based Geometric Design and Finite Element Analysis Study.Cureus · 2026
- In silico biomechanical evaluation of personalized A-shaped titanium plates for mandibular condylar base fractures.Computer methods in biomechanics and biomedical engineering · 2026
- Towards minimally invasive prosthetic surgery of the temporomandibular joint: design and integrated CAD-FEM preclinical approach on the mini-pig.Computer methods in biomechanics and biomedical engineering · 2026