Verification and optimization of impact-response consistency in human thoracic targets for blunt ballistic impact testing.
Jiakai Wu, Song Wang, Jiaming Song, Jingpeng Wu, Bin Chen, Zhihua Cai
School of Equipment Management & Support, Chinese People's Armed Police Force Engineering University, Xi'an, China. · School of Mechanical and Electrical Engineering, Hunan University of Science and Technology, Xiangtan, China.
Key points
From the paper's conclusion- The coefficients of variation ranged from 2.74% to 12.20%, indicating acceptable experimental repeatability. The results show that both the physical target with PA66+GF30 ribs and the CHEST digital target meet the standard requirements for displacement-time curves and peak viscous response values. Using the physical test results as a reference, LS-OPT and the sequential response surface method were employed to optimize the Young's modulus of costal cartilage in the digital target. After optimization, the normalized mean absolute error of the displacement response between the physical and digital targets decreased from 4.8% to 3.4% at 56 m/s and from 12.5% to 4.9% at 86.5 m/s, greatly improving consistency.
Abstract
INTRODUCTION: The validation of human thorax targets for blunt ballistic impact injury assessment is a critical component in investigating their impact responses. Existing studies generally validate physical and finite-element (FE) thoracic targets independently against standardized response corridors. However, whether these two targets produce quantitatively consistent responses under identical blunt ballistic impact conditions remains insufficiently investigated. METHODS: To resolve the discrepancy in impact responses between physical and digital thorax targets and establish a verification method for the consistency of blunt impact responses between physical and digital human thoracic targets for non-lethal kinetic projectiles, a 3-rib physical thoracic target with ribs made of three different materials was constructed, and the CHEST finite-element model was selected as the digital target. According to AEP-99 standards, blunt impact tests and numerical simulations of SIR-X projectiles were conducted at impact velocities of 56 m/s and 86.5 m/s. Each impact condition was tested three times, and the repeatability and uncertainty were evaluated using the coefficient of variation. RESULTS: The coefficients of variation ranged from 2.74% to 12.20%, indicating acceptable experimental repeatability. The results show that both the physical target with PA66+GF30 ribs and the CHEST digital target meet the standard requirements for displacement-time curves and peak viscous response values. Using the physical test results as a reference, LS-OPT and the sequential response surface method were employed to optimize the Young's modulus of costal cartilage in the digital target. After optimization, the normalized mean absolute error of the displacement response between the physical and digital targets decreased from 4.8% to 3.4% at 56 m/s and from 12.5% to 4.9% at 86.5 m/s, greatly improving consistency. DISCUSSION: Thus, this study demonstrates that the proposed verification method effectively enhances the biomechanical reliability of digital thoracic targets. The validated physical and digital targets can provide standardized testing and technical support for thoracic injury assessment, experimental validation, and safety design of non-lethal kinetic projectiles.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of a finite element model specific to the female thorax for non-penetrating ballistic impact.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026
- Measurement and comparison of thoracic viscous response between the Chinese anthropomorphic test device and hybrid III.Traffic injury prevention · 2026
- Material and Structural Properties of Adult Human Ribs: A Systematic Review and Test-Condition-Specific Evidence for Thoracic Biofidelity Assessment and Human Surrogate Development.Annals of biomedical engineering · 2026
- Material response under localised loading: proposed alternatives to ballistic gelatine for wound ballistics research.Forensic science, medicine, and pathology · 2026
- Physiology-Based Liver Injury Criteria for Behind Armor Blunt Trauma.Military medicine · 2026
- Ballistic gelatin as a soft tissue simulant: A systematic review of applications, calibration methods, and synthetic alternatives.Journal of forensic sciences · 2026