Annals of biomedical engineering

Material and Structural Properties of Adult Human Ribs: A Systematic Review and Test-Condition-Specific Evidence for Thoracic Biofidelity Assessment and Human Surrogate Development.

Marcin Jenerowicz, Amanda Agnew, Yun-Seok Kang, Stefan Hiermaier

Department of Dynamics of Materials, Simulation Methods and Digitalization, Fraunhofer Institute for High-Speed Dynamics, Ernst-Mach-Institute, EMI, Ernst-Zermelo-Straße 4, 79104, Freiburg, Germany. marcin.jenerowicz@emi.fraunhofer.de. · Injury Biomechanics Research Center, The Ohio State University, 333 W 10th Ave, Columbus, OH, 43210, USA.

Review

Key points

From the paper's conclusion
  • This systematic review synthesized test-condition-specific evidence on the material and structural properties of adult human ribs from post-mortem human subjects (PMHS) experiments and evaluated a defined whole-rib dataset.

Abstract

This systematic review synthesized test-condition-specific evidence on the material and structural properties of adult human ribs from post-mortem human subjects (PMHS) experiments and evaluated a defined whole-rib dataset. Searches of bibliographic databases, proceedings, citation sources, and technical reports identified 2,116 records; 48 bibliographic evidence reports were included. Evidence was organized into cortical tensile coupon, three-point bending, whole-rib anterior-posterior (A-P), and other method-specific strata because these configurations quantify distinct local material, segmental flexural, and global structural responses. Cross-study meta-analysis was not performed because of substantial heterogeneity in specimen preparation, loading configuration and rate, boundary conditions, geometry measurement, instrumentation, outcome definition, and data availability. The active evidence base comprised 53 test components represented by 57 assessment units. The Ohio State University rib structural dataset included 297 fractured adult ribs from 164 donors tested in a defined dynamic pinned-cap A-P configuration. Primary donor-clustered mixed-effects models were restricted to rib levels 4-7: 295 ribs for peak force, total energy, and normalized peak displacement, and 294 ribs for stiffness. Age was modeled linearly for peak force and stiffness and with three-knot restricted cubic spline functions for total energy and normalized peak displacement. The evidence supports configuration-matched validation of rib material models, rib-segment models, and whole-rib simulations, and informs thoracic biofidelity assessment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers