Measurement and comparison of thoracic viscous response between the Chinese anthropomorphic test device and hybrid III.
Jingkai Cui, Hanxiao Zhang, Kai Wang, Zhengqi Fan, Weidong Liu, Zhixin Liu
Central Research Institute, China Automotive Technology and Research Center Co., Ltd, Tianjin, China.
Key points
From the paper's conclusion- The proposed methods can effectively measure the thoracic VC of the ATDs. Under lower impact energy, the internal thoracic deformation velocity and peak VC of the CN-50M were both significantly higher than those of the HIII-50M.
Abstract
OBJECTIVE: Anthropomorphic test devices (ATDs) are essential tools for estimating occupant injury risks under controlled impact conditions. Viscous response (VC) is one of the important criteria for assessing the risk of thoracic injury. However, the thoracic displacement sensor in the existing Hybrid III ATD cannot directly measure or calculate VC. This article aims to establish general methods for measuring the thoracic VC of ATDs, and to obtain and compare the thoracic VC of an ATD representing the 50th percentile Chinese adult male (CN-50M) with that of the Hybrid III 50th percentile male ATD (HIII-50M). METHODS: Thoracic VC is calculated from external chest deformation, which includes the viscoelastic properties of the thoracic skin. Two methods for measuring external chest deformation during thoracic impact tests are proposed: (1) External deformation is obtained by subtracting the dummy's shoulder displacement from the impactor displacement, both measured using a high-speed camera. (2) External deformation is obtained by subtracting the dummy's thoracic spine displacement, measured using a string potentiometer, from the impactor displacement, measured using a high-speed camera. A total of nine impact tests were conducted on two CN-50M and three HIII-50M dummies on the thoracic calibration test bench. The pendulum mass was 19.78 kg for the CN-50M tests and 23.36 kg for the HIII-50M tests, with an impact velocity of 6.7 m/s in both cases. RESULTS: The average peak internal thoracic VC of the CN-50M was 0.8019 m/s, which is 19.63% higher than that of the HIII-50M (0.6703 m/s), while the peak external thoracic VC of the CN-50M was comparable to that of the HIII-50M. The recommended values of the external-to-internal VC scaling factor for the CN-50M and HIII-50M are 1.63 and 2.03, respectively. CONCLUSIONS: The proposed methods can effectively measure the thoracic VC of the ATDs. Under lower impact energy, the internal thoracic deformation velocity and peak VC of the CN-50M were both significantly higher than those of the HIII-50M.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Verification and optimization of impact-response consistency in human thoracic targets for blunt ballistic impact testing.Frontiers in bioengineering and biotechnology · 2026
- Pedestrian injury risk in sedan, SUV, and pickup impacts using an improved human body model.Traffic injury prevention · 2026
- Improvement and evaluation of the 50th percentile female prototype rear impact dummy, BioRID P50F.Frontiers in bioengineering and biotechnology · 2026
- The impact of head and thorax elevation on respiratory mechanics during cardiopulmonary resuscitation: a multi-model study.Resuscitation plus · 2026
- Development of a finite element model specific to the female thorax for non-penetrating ballistic impact.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026
- Tissue-level distal tibia simulations to assess strain as a predictor of AIS 2 ankle injuries.Traffic injury prevention · 2026