Frontiers in Acoustics

Feasibility of transcranial ultrasound–photoacoustic tomography for guidance and monitoring of laser interstitial thermal therapy

Liumei Ma, Hossein Raeis, Thomas Marini, Tyler Schmidt, Nebojsa Duric, Mohammad Mehrmohammadi

Key points

From the paper's conclusion
  • Introduction Laser interstitial thermal therapy is a minimally invasive treatment for intracerebral tumors, epileptogenic foci, and radiation necrosis, for which accurate applicator localization and treatment monitoring remain essential for safe and effective therapy.

Abstract

Introduction Laser interstitial thermal therapy is a minimally invasive treatment for intracerebral tumors, epileptogenic foci, and radiation necrosis, for which accurate applicator localization and treatment monitoring remain essential for safe and effective therapy. Intraoperative magnetic resonance imaging (iMRI) is the current standard for guidance, but its high cost, limited portability, and procedural complexity motivate alternative real-time imaging approaches. This study investigates a transcranial photoacoustic tomography (TcPAT) and transcranial ultrasound tomography (TcUST) platform that combines photoacoustic (PA) fiber-tip localization with quantitative sound-speed (SS) imaging and temperature-related SS monitoring. Methods A low-frequency ring-array transducer was used to acquire TcPAT and TcUST data through an excised human skull. Pulsed laser excitation was delivered through the optic fiber to generate a localized PA signal at the fiber tip. Computed Tomography (CT)-derived skull SS maps were registered to the ultrasound coordinate system, and skull-informed travel times correction were incorporated into the TcPAT reconstruction. Fiber-tip localization was evaluated at five known positions and compared with Bmode reference locations. Frequency-domain full-waveform inversion was used to reconstruct SS images from TcUST data. SS contrast recovery through the skull was evaluated using a lesion-mimicking phantom. UST data were repeatedly acquired as the target-region temperature changed and used to reconstruct SS images. The relationship between the reconstructed SS shifts and temperature changes was evaluated. Results Results demonstrated that the integrated system could localize the PA signal from the laser fiber through the skull and improve localization accuracy with CT-assisted acoustic correction. TcUST recovered a detectable SS contrast between the gelatin phantom and the water inclusion, with measured contrasts of approximately 30 m/s without the skull and 20 m/s through the skull. As the target region temperature decreased from 67 °C to 37 °C, temperature-dependent SS changes were observed, following the reference trend with a best R 2 of 0.97 and a fitted slope of 1.007. Conclusion This proof-of-concept study provides preliminary evidence supporting the potential of the proposed platform for applicator localization, structural SS imaging, and SS-based treatment monitoring as a complement to iMRI.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers