Journal of Applied Physics

Diffusion-constrained delay-domain selection for rapid enhanced truncated-correlation photothermal coherence tomography imaging of vascular-like structures in the intact mouse head

Hong Tang, Cong Zhang, Andreas Mandelis, Hai Zhang

Key points

From the paper's conclusion
  • Overall, eTC-PCT parameter selection requires a multi-metric trade-off among CNR, apparent FWHM, boundary gradient, anatomical interference, acquisition time, and exposure.

Abstract

Non-contact photothermal imaging can probe optically absorbing structures through the intact scalp, but delay-resolved enhanced truncated-correlation photothermal coherence tomography (eTC-PCT) maps are shaped by thermal diffusion, correlation gating, and anatomical interference. A quantitative rule is, therefore, required for selecting excitation and reconstruction parameters without relying on a visually brightest amplitude slice. A framework combining fixed-region-of-interest analysis, numerical phantom analysis, and multiple image metrics was developed for rapid eTC-PCT imaging of vascular-like structures in the intact mouse head. Full delay-sequence analysis was performed on three independently acquired in vivo datasets, one from each animal. Each dataset contained 593 correlated amplitude slices. Maximum contrast-to-noise ratio (CNR) reached 3.13 at 710 ms, whereas apparent FWHM increased from approximately 12.4 to 23.6 pixels across the identifiable delay range. The minimum eye-to-target response ratio occurred at a delay with reduced CNR. Numerical absorbing-tube phantom analysis further showed that delay-resolved maps should be interpreted through detectability and diffusion-broadened apparent width, rather than as uncalibrated geometric depth sections. A 14 s acquisition reduced imaging time to 17.3% of an 81 s reference, corresponding to a 5.79-fold acceleration and a relative dose of 0.173 under matched exposure. The 0.2–0.6 Hz, 0.1 s, and 14 s protocol is, therefore, considered a practical option under the present experimental conditions rather than a universal optimum. Overall, eTC-PCT parameter selection requires a multi-metric trade-off among CNR, apparent FWHM, boundary gradient, anatomical interference, acquisition time, and exposure.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Diffusion-constrained delay-domain selection for rapid enhanced truncated-correlation photothermal coherence tomography imaging of vascular-like structures in the intact mouse head — Science Skim