MiniMed 780G Advanced Hybrid Closed-Loop System Use During Days Without User-Initiated Boluses
Fang Niu, Margaret Liu, Caroline Yovanovich, Robert A. Vigersky, John J. Shin, Jennifer McVean
Medtronic (Ireland)
Key points
From the paper's conclusion- These data demonstrate effective glycemic control with the MM780G system on days when some users did not initiate boluses.
Abstract
OBJECTIVE: To evaluate glycemic metrics and insulin delivery during real-world use of the MiniMed 780G (MM780G) system on days when users did not administer boluses. RESEARCH DESIGN AND METHODS: Global CareLink personal data of consenting MM780G users (N = 369,467) uploaded from 2 January 2020 to 31 March 2025 were analyzed. Among these individuals, 54,553 users experienced ≥10 days without any user-initiated boluses. Evaluated key metrics included time in range (TIR; 70-180 mg/dL), time below range (TBR; <70 mg/dL), time above range (>180 mg/dL), the glucose management indicator (GMI), and total insulin delivered. These were analyzed for the overall population who did not initiate boluses and for those who used and did not use recommended optimal settings (ROS; defined as a 100 mg/dL glucose target and a 2-h active insulin time). Subgroup analyses were conducted by age (≤15 or >15 years) and diabetes type (type 1 or 2). RESULTS: On days when boluses were missed, ROS users had a mean sensor glucose (SG) of 149.2 mg/dL, with mean TIR, TBR, and GMI of 76.3%, 0.8%, and 6.9%, respectively, whereas non-ROS users had a mean SG of 159.7 mg/dL with mean TIR, TBR, and GMI of 69.3%, 0.9%, and 7.1%, respectively. ROS use was associated with more individuals achieving consensus TIR, TBR, and GMI goals. CONCLUSIONS: These data demonstrate effective glycemic control with the MM780G system on days when some users did not initiate boluses. A greater proportion of real-world users achieved glycemic goals when ROS were used.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sustained Glycemic Outcomes in Children: A Three-Year Real-World Follow-Up of the MiniMed™ 780G System.Hormone research in paediatrics · 2026
- Prospective multicenter evaluation of glycemic and patient-reported outcomes following transition to a next-generation continuous glucose monitoring system in users of advanced hybrid closed-loop technologyTherapeutic Advances in Endocrinology and Metabolism · 2026
- The Automatic Correction Boluses in an Advanced Hybrid Closed-Loop System: Algorithm Performance and Clinical ImplicationsJournal of Diabetes Science and Technology · 2026
- Sustained Glycemic Outcomes with the MiniMed™ 780G System: Real-World Evidence from >16,000 Users Across 18 Latin American Countries Over Two Years.Diabetes technology & therapeutics · 2026
- Real-World MiniMed™ 780G Advanced Hybrid Closed-Loop Performance Across the Asia-Pacific Region.Diabetes technology & therapeutics · 2026
- Improved glycemic control with the MiniMed 780G system in latent autoimmune diabetes and type 1 diabetes: a real-world observational study.Diabetes research and clinical practice · 2026