Prospective multicenter evaluation of glycemic and patient-reported outcomes following transition to a next-generation continuous glucose monitoring system in users of advanced hybrid closed-loop technology
Lía Nattero-Chávez, MAR LORENZO, María Soledad Ruiz de Adana, Olga Simó-Servat, Mercè Abad, Carmen Quirós, María Durán Martínez, Alejandra Quintero Tobar,
Centro de Investigación Biomédica en Red Diabetes y Enfermedades Metabólicas Asociadas · Hospital Universitario Ramón y Cajal
Key points
From the paper's conclusion- Conclusion: In Control-IQ users, the transition to G7 ® did not significantly impact glycemic control overall.
Abstract
Aims: To assess the real-world impact of transitioning from the Dexcom G6 ® to G7 ® system in individuals with type 1 diabetes (T1D) using the Tandem t:slim X2™ with Control-IQ™. Primary outcomes included glycemic control changes, while secondary outcomes evaluated patient-reported outcomes (PROMs) and experiences (PREMs). Methods: A 3-month prospective, multicenter, observational study was conducted in individuals previously using Dexcom G6 and Control-IQ. Glycemic control was assessed via TIR 70–180 and HbA 1c . PREMs and PROMs were measured using validated questionnaires (Diabetes Quality of Life (DQoL), Type 1 Diabetes Life (ViDa1), Diabetes Distress Scale (DDS), and Diabetes Treatment Satisfaction Questionnaire). Statistical analyses were stratified by baseline TIR 70–180 (>70% vs <70%) and sex. Results: The study included 92 participants (mean age 38 ± 13 years), with a baseline TIR 70–180 of 76% ± 10%. The overall TIR 70−180 remained stable throughout the study. However, among participants with baseline TIR 70–180 <70%, a significant increase in TIR 70−180 was observed, rising from 61% ± 9% to 65% ± 7% ( p = 0.007). In consonance, HbA 1c levels showed a significant decline, from 7.3% ± 0.9% to 7.0% ± 0.6% ( p = 0.001). In addition, both glucose management indicator (GMI) and mean glucose levels significantly decreased over time, reflecting an overall improvement in glycemic control. These changes (GMI and glucose levels) were consistent across groups, with no significant differences based on baseline TIR 70-180 stratification. Quality of life and diabetes distress improved (DQoL, ViDa1, and DDS), especially in participants with lower baseline TIR 70-180 and in women. Some reported increased connectivity issues, but none led to treatment discontinuation. Conclusion: In Control-IQ users, the transition to G7 ® did not significantly impact glycemic control overall. However, a subgroup of patients with suboptimal baseline control (TIR 70–180 <70%) may benefit from this change, and enhanced quality of life and diabetes distress, especially in women.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improvement in Tight Glycemic Control in Adults with Type 1 Diabetes Using the MiniMed™ 780G Hybrid Closed-Loop System: A Real-World Evaluation.Current diabetes reviews · 2026
- MiniMed 780G Advanced Hybrid Closed-Loop System Use During Days Without User-Initiated BolusesDiabetes Care · 2026
- Glycemic And Patient-Reported Outcomes After Transition To Advanced Hybrid Closed-Loop System In Patients After Total Pancreatectomy.The Journal of clinical endocrinology and metabolism · 2026
- Two-Year Real-Life Achievements of MiniMed 780G Advanced Closed-Loop System in Youth with Type 1 Diabetes: AWeSoMe Study Group Multicenter Prospective Extended Follow-Up.Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists · 2026
- Sustained Glycemic Outcomes in Children: A Three-Year Real-World Follow-Up of the MiniMed™ 780G System.Hormone research in paediatrics · 2026
- Six-month real-world glycemic improvement after Smart MDI system in type 1 diabetes.Journal of the Endocrine Society · 2026