Fatal Delayed Stent-edge Rupture Confirmed by Autopsy after Stent-assisted Coil Embolization for a Blood Blister-like Aneurysm.
Akina Hirohashi, Masahiro Nishihori, Takashi Izumi, Shunsaku Goto, Satoshi Ito, Nobuhiko Mizutani, Hiroki Shimizu, Ryuichi Fukuyama,
Department of Neurosurgery, Konan Kosei Hospital, Konan, Aichi, Japan. · Department of Neurosurgery, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan.
Key points
From the paper's conclusion- We report the case of a 42-year-old woman with a ruptured blood blister-like aneurysm arising from the anterior wall of the internal carotid artery who was treated with stent-assisted coil embolization.
Abstract
Blood blister-like aneurysms of the internal carotid artery are uncommon lesions that often present with subarachnoid hemorrhage and are considered part of the spectrum of intracranial arterial dissections. Although endovascular treatment options have expanded in recent years, serious complications remain a clinical concern. We report the case of a 42-year-old woman with a ruptured blood blister-like aneurysm arising from the anterior wall of the internal carotid artery who was treated with stent-assisted coil embolization. The initial postoperative course was uneventful and follow-up imaging showed no evidence of aneurysmal recurrence. However, the patient died 3 months after treatment. Autopsy revealed rupture of the parent artery at the opposite wall of the distal stent edge, with extravascular exposure of the stent. Histopathological examination demonstrated disruption of the internal elastic lamina extending both distal and proximal to the aneurysm, indicating that arterial dissection was more extensive than detectable by angiography. This case suggests that multiple factors, including stent-induced vessel straightening, incomplete wall apposition, antithrombotic therapy, and pre-existing wall fragility, may contribute to delayed stent-edge rupture following stent-assisted coil embolization for blood blister-like aneurysms. Careful selection of stent type and length to adequately cover the dissected segment may be important to reduce the risk of delayed parent artery failure.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A ruptured internal carotid artery blood blister-like aneurysm with rebleeding after single-layer neck-bridging stenting and complete obliteration after double-layer stenting: A case report.Surgical neurology international · 2026
- Delayed angiographic detection of a ruptured basilar artery perforator aneurysm in diffuse initially angiographically occult subarachnoid hemorrhage: A case report and literature review.Journal of cerebrovascular and endovascular neurosurgery · 2026
- Advances in the treatment of intracranial blood blister-like aneurysms: a comprehensive review from surgical approaches to endovascular therapy.Frontiers in neurology · 2026
- Pipeline embolization device with adjunctive coiling for ruptured blood blister-like aneurysms: a multicenter study focusing on Hunt-Hess grade I-III patients.Frontiers in neurology · 2026
- "Small ghost aneurysm": delayed visualization of a ruptured thrombosed nonbranching M2 aneurysm with pathological and hemodynamic correlation. Illustrative case.Journal of neurosurgery. Case lessons · 2026
- Delayed Aneurysmal Rupture following Flow Diverter Placement despite Adjunctive Coiling: Case Report.Case reports in neurology · 2026