Delayed Aneurysmal Rupture following Flow Diverter Placement despite Adjunctive Coiling: Case Report.
Mikael Aseged Shimekit, Samuel Masresha Fetene, Eskedar Kebede Belayneh, Kaleab Eticha, Michael Yirgalem Teka, Eden Enyew Zeleke, Bisrat Germame, Meti Taye,
Axon Stroke and Spine Center, Addis Ababa, Ethiopia.
Key points
From the paper's conclusion- Delayed rupture of an aneurysm following Surpass Evolve flow diverter embolization is a rare complication associated with high morbidity and mortality. In our case, in-stent thrombosis occurred on postoperative day 4 and subsequently progressed to aneurysmal rupture, despite the presence of coils within the aneurysm sac. Rupture on the fourth day after Surpass Evolve flow diverter placement - despite initial coil embolization - along with aneurysmal thrombosis, partial recanalization, thrombus extension into the parent vessel, and subsequent treatment with intra-arterial eptifibatide and tenecteplase highlights the profound hemodynamic instability in giant aneurysms that can contribute to post-procedural rupture.
Abstract
INTRODUCTION: Flow diverters significantly alter the inflow dynamics of an aneurysm, leading to both qualitative and quantitative changes in the intra-aneurysmal hemodynamic environment (AJNR Am J Neuroradiol. 2014 Aug 1;35(8):1567-73). CASE PRESENTATION: A 65-year-old woman with a giant left internal carotid artery aneurysm causing visual symptoms underwent treatment with coiling, Surpass Evolve flow diverter placement, and balloon angioplasty. Despite being on dual antiplatelet therapy, she developed in-stent thrombosis on postoperative day 4, leading to neurological symptoms. Intra-arterial thrombolysis with eptifibatide and tenecteplase achieved near total recanalization and initial clinical improvement. However, she subsequently developed a massive subarachnoid hemorrhage and was declared brain dead the next day. CONCLUSION: Delayed rupture of an aneurysm following Surpass Evolve flow diverter embolization is a rare complication associated with high morbidity and mortality. In our case, in-stent thrombosis occurred on postoperative day 4 and subsequently progressed to aneurysmal rupture, despite the presence of coils within the aneurysm sac. Rupture on the fourth day after Surpass Evolve flow diverter placement - despite initial coil embolization - along with aneurysmal thrombosis, partial recanalization, thrombus extension into the parent vessel, and subsequent treatment with intra-arterial eptifibatide and tenecteplase highlights the profound hemodynamic instability in giant aneurysms that can contribute to post-procedural rupture.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ischemic complication in the anterior thalamoperforating artery territory following flow diverter stent placement for an internal carotid-posterior communicating artery aneurysm.Surgical neurology international · 2026
- Periprocedural (≤72 hours) safety of flow diverters versus alternative endovascular techniques for unruptured intracranial aneurysms.Journal of neurointerventional surgery · 2026
- Intracranial Aneurysm Complicated by Common Carotid Artery Infarction Following FDS Procedure.The Journal of craniofacial surgery · 2026
- Incidence and risk factors for delayed structural changes in Pipeline Embolization DevicesJournal of NeuroInterventional Surgery · 2026
- Factors Associated with Aneurysm Occlusion after Flow Diverter Treatment.Journal of neuroendovascular therapy · 2026
- Fatal Delayed Stent-edge Rupture Confirmed by Autopsy after Stent-assisted Coil Embolization for a Blood Blister-like Aneurysm.NMC case report journal · 2026