Pipeline embolization device with adjunctive coiling for ruptured blood blister-like aneurysms: a multicenter study focusing on Hunt-Hess grade I-III patients.
Peiming Wang, Jie Liu, Huaitao Yuan, Feng Xu, Wei Tang, Qiming Li, Lukui Chen
Department of Neurosurgery, Southern Medical University Hospital of Integrated Traditional Chinese and Western Medicine, Southern Medical University, Guangzhou, China. · Department of Neurosurgery, Guangdong Sanjiu Brain Hospital, Guangzhou, China.
Key points
From the paper's conclusion- Evidence regarding the outcomes of Pipeline embolization device (PED)-assisted coiling specifically in patients with mild-to-moderate neurological deficits (Hunt-Hess grade I-III) remains limited.
Abstract
BACKGROUND: Blood blister-like aneurysms (BBAs) of the internal carotid artery are rare and inherently unstable lesions that carry a high risk of rebleeding. Evidence regarding the outcomes of Pipeline embolization device (PED)-assisted coiling specifically in patients with mild-to-moderate neurological deficits (Hunt-Hess grade I-III) remains limited. METHODS: This multicenter retrospective study, conducted at three comprehensive stroke centers between January 2018 and December 2023, included 28 consecutive patients with ruptured ICA BBAs. We evaluated the safety and efficacy of PED combined with adjunctive coil embolization using a deliberate loose-scaffolding strategy. RESULTS: Technical success was achieved in 100% of cases. Immediate complete angiographic occlusion (modified Raymond-Roy class I) was observed in 67.9% (19/28), increasing to 75.0% (21/28) overall at 12 months and reaching 95.5% (21/22) among those with available imaging follow-up. Notably, all seven patients with residual neck filling on immediate postoperative angiography who completed follow-up subsequently achieved complete occlusion. Favorable clinical outcome (modified Rankin Scale 0-2) was recorded in 92.9% (26/28) at last follow-up. Perioperative complications occurred in 39.3% (11/28), predominantly neurological, including symptomatic vasospasm (21.4%, 6/28) and cerebral infarction (14.3%, 4/28); perioperative mortality was 3.6% (1/28). CONCLUSION: PED-assisted coil embolization with a loose-scaffolding strategy is technically feasible and may yield favorable outcomes in selected patients with mild-to-moderate neurologic deficits. However, given the retrospective, single-arm design and modest sample size, these results are hypothesis-generating; prospective comparative studies are warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Advances in the treatment of intracranial blood blister-like aneurysms: a comprehensive review from surgical approaches to endovascular therapy.Frontiers in neurology · 2026
- A ruptured internal carotid artery blood blister-like aneurysm with rebleeding after single-layer neck-bridging stenting and complete obliteration after double-layer stenting: A case report.Surgical neurology international · 2026
- Multicenter experience of pipeline embolization device used in small caliber vessels (< 2 mm) for intracranial aneurysm treatment and mid-term resultsFrontiers in Neurology · 2026
- Comparison of Early versus Delayed Flow Diverter Implantation on Rebleeding and Clinical Outcomes in Patients with Ruptured Blood Blister-Like AneurysmWorld Neurosurgery · 2026
- Fatal Delayed Stent-edge Rupture Confirmed by Autopsy after Stent-assisted Coil Embolization for a Blood Blister-like Aneurysm.NMC case report journal · 2026
- Outcome of late microsurgical clipping for ruptured cerebral aneurysms: a retrospective studyEgyptian Journal of Neurosurgery · 2026