Pupillary and Oculomotor Responses to Conventional Near Viewing and a Long-Distance Optical Imaging Workbench in Children.
Shuo Wu, Yumeng Li, Hao Fu, Wanting Liu, Kai Wang
Department of Ophthalmology, Peking University People's Hospital, Beijing, People's Republic of China.
Key points
From the paper's conclusion- LOIW viewing was associated with larger pupils, longer fixation duration, and greater saccade amplitude in pixels than Near viewing. The fixed viewing order, target magnification, and unmeasured target luminance limit interpretation. These findings do not establish reduced accommodation, improved visual comfort, or efficacy in myopia control.
Abstract
PURPOSE: To compare binocular pupil diameter and selected oculomotor measures during far viewing (Far), conventional near viewing (Near), and viewing through a long-distance optical imaging workbench (LOIW) in children. METHODS: Of 86 children enrolled in this single-center repeated-measures study, three were excluded because of missing eye-tracking data; data from 83 children aged 8 to 15 years were analyzed. Children fixated a stationary cross in the fixed sequence of Far, Near, and LOIW. After two minutes of adaptation, children viewed the target for one minute, with a 10-second recording obtained once fixation appeared stable. Conditions were separated by one minute of rest. Measured illuminance was the same for Near and LOIW. Pupil diameter was analyzed using a linear mixed-effects model with a random intercept for each participant. Exploratory paired comparisons of fixation duration, saccade amplitude in pixels, and software-reported saccade frequency were adjusted using Holm's method across nine tests. RESULTS: Mean pupil diameter was 4.87 ± 0.71 mm during Far, 2.93 ± 0.54 mm during Near, and 4.23 ± 0.69 mm during LOIW. The mean difference in pupil diameter between LOIW and Near was 1.30 mm (95% CI, 1.12 to 1.48; Holm-adjusted P < 0.001). Compared with Near, LOIW was associated with longer fixation duration (difference, 19.61 ms; 95% CI, 14.56 to 24.67; adjusted P < 0.001) and greater saccade amplitude in pixels (difference, 10.77 px; 95% CI, 4.48 to 17.06; adjusted P = 0.005). Software-reported saccade frequency did not differ significantly among conditions. CONCLUSION: LOIW viewing was associated with larger pupils, longer fixation duration, and greater saccade amplitude in pixels than Near viewing. The fixed viewing order, target magnification, and unmeasured target luminance limit interpretation. These findings do not establish reduced accommodation, improved visual comfort, or efficacy in myopia control.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pupil size measurements with two multifunctional devices based on different technologies and an infrared based pupillometer.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
- A comparative analysis of pupillometry measurements obtained from different devices featuring static and dynamic capabilities.Documenta ophthalmologica. Advances in ophthalmology · 2026
- Oculomotor Profiles in Children Wearing Different Myopia Control Lenses: A Real-World Eye Tracking Study.Vision (Basel, Switzerland) · 2026
- Effects of Spatial Ambient Illumination on Pupil Diameter and Visual Acuity.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026
- Age-corrected model for predicting pupil diameter in real-world conditions from melanopic equivalent daylight illuminancebioRxiv · 2026
- Clinical utility of pupil diameter cutoffs for detecting early presbyopia.Japanese journal of ophthalmology · 2026