Nd:YAG Capsulotomy Rates of Three FineVision Trifocal Intraocular Lens Platform Across Different Platforms: Results from a Multicenter Clinical Registry Study.
Fernando Llovet-Osuna, Jaime Beltran-Sanz, Andrea Llovet-Rausell, Vasyl Druchkiv, Julio Baviera-Sabater
Department of Cataract and Refractive Surgery, Clínica Baviera (AIER Eye Hospital Group), Madrid, Spain. · Department of Research and Development Clínica Baviera - AIER Eye Hospital Group, Valencia, Spain.
Key points
From the paper's conclusion- Nd:YAG capsulotomies rates varied accordingly to the FineVision IOL model. Differences in IOL material (hydrophilic or hydrophobic) and haptic design (4-closed loops or a double C-loop) could account for these differences.
Abstract
PURPOSE: To report the neodymium:yttrium-aluminum-garnet (Nd:YAG) laser capsulotomy rates following implantation of three models of the FineVision (BVI Inc. Waltham, USA) diffractive trifocal intraocular lens (IOL). METHODS: This was a multicentre, retrospective study including eyes implanted with the FineVision Micro F, FineVision POD/POD FT and the FineVision HP (POD F GF) IOL models after uncomplicated cataract or refractive lens exchange surgeries. The rate of Nd:YAG laser capsulotomy (cumulative incidence) during 1, 3, 5 and 10 years of follow-up were recorded. RESULTS: 190,567 eyes implanted with the three FineVision IOL models were analysed: 170,047 eyes with the FineVision Micro F IOL model, 20,174 eyes with the FineVision POD IOL model, and 346 eyes with the FineVision HP IOL model. Cumulative incidence of Nd:YAG capsulotomy was 3% at 1 year, 6.2% at 3 years, 8.4% at 5 years and 10.9% of eyes at 10 years for the FineVision Micro F IOL model. For the FineVision POD/POD FT IOL model percentages were 6.9% at 1 year, 24.3% at 3 years, and 36.8% of eyes at 5 years. Finally, for the FineVision HP IOL model the percentage at 1 year of follow-up was 6.9% of eyes. CONCLUSION: Nd:YAG capsulotomies rates varied accordingly to the FineVision IOL model. Differences in IOL material (hydrophilic or hydrophobic) and haptic design (4-closed loops or a double C-loop) could account for these differences.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical Outcomes of the First Diffractive Trifocal Intraocular Lens: A Literature Review.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Comparative Two-Year Outcomes of Three Different Three-Piece Intraocular Lenses in Flanged Intrascleral Fixation.Medicina (Kaunas, Lithuania) · 2026
- Comparative Clinical Outcomes Between Successive Generations of Liberty Trifocal Intraocular Lenses.Journal of clinical medicine · 2026
- Comparative safety and complication profiles of two three-piece intraocular lenses in Yamane technique.International ophthalmology · 2026
- Bilateral Refractive Lens Exchange with a Hydrophobic Trifocal Intraocular Lens.Clinical ophthalmology (Auckland, N.Z.) · 2026
- A Comparative Study of the Visual Outcomes of Two Common Diffractive Trifocal Intraocular Lenses in a Matched Cohort.Cureus · 2026