Clinical Outcomes of the First Diffractive Trifocal Intraocular Lens: A Literature Review.
Damien Gatinel, Christophe Pagnoulle, Fernando Llovet-Osuna, Robert Edward T Ang, Takayuki Akahoshi
The Foundation Rothschild Hospital, Paris, France. · Research and Development Department, BVI, Liège, Belgium.
Key points
From the paper's conclusion- The outcomes analyzed in the present review lead us to conclude that FineVision diffractive trifocal IOLs provide good clinical performance when implanted. The most up-to-date FineVision HP model, hydrophobic with a double C-loop, provides excellent refractive accuracy, good visual performance, and patient satisfaction with high spectacle independence.
Abstract
PURPOSE: The purpose of this review article is to summarise the clinical outcomes reported in patients implanted with FineVision diffractive trifocal intraocular lenses (IOLs). METHODS: We searched the PubMed (US National Library of Medicine) and Scopus (Elsevier) databases on 18 October 2025. We included any type of prospective or retrospective study published in a peer-reviewed journal reporting the clinical outcomes of patients who were implanted with the FineVision Micro F, FineVision POD/POD FT or the FineVision HP (POD F GF/POD FT 49P) IOL models after cataract or refractive lens exchange surgeries. RESULTS: A total of 97 clinical studies published between 2012 and 2025 were obtained, and, of these, the three with the maximum number of eyes recruited and the longest follow-up per IOL model were included in this review. The most important data in these 9 publications was analysed, considering refractive accuracy, rotation stability, visual acuity at different distances (far, intermediate and near), defocus curves, photopic and mesopic contrast sensitivity, patient-reported outcome questionnaires, ocular aberrations, light distortion, photic phenomena and adverse events. CONCLUSION: The outcomes analyzed in the present review lead us to conclude that FineVision diffractive trifocal IOLs provide good clinical performance when implanted. The most up-to-date FineVision HP model, hydrophobic with a double C-loop, provides excellent refractive accuracy, good visual performance, and patient satisfaction with high spectacle independence.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Visual, refractive and patient-reported outcomes after two trifocal intraocular lens designs: a 12-month comparative cohort study.BMC ophthalmology · 2026
- Comparison of clinical outcomes of trifocal versus extended depth of focus intraocular lenses: meta-analysis of randomized controlled trials.BMC ophthalmology · 2026
- Nd:YAG Capsulotomy Rates of Three FineVision Trifocal Intraocular Lens Platform Across Different Platforms: Results from a Multicenter Clinical Registry Study.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Bilateral Refractive Lens Exchange with a Hydrophobic Trifocal Intraocular Lens.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Visual and refractive evaluation of two diffractive trifocal intraocular lens platforms with distant and near dominant light energy distributions.International journal of ophthalmology · 2026
- Comparative Clinical Outcomes Between Successive Generations of Liberty Trifocal Intraocular Lenses.Journal of clinical medicine · 2026