Bilateral Refractive Lens Exchange with a Hydrophobic Trifocal Intraocular Lens.
Camille Bosc, Eloïse Le Malefan, Pauline Boury, Mélanie Bernier
Research Clinic Department, Institut Ophtalmologique de l'Ouest (IOO) Jules Verne, Nantes, France.
Key points
From the paper's conclusion- The FineVision HP IOL demonstrated favorable short-term refractive accuracy and visual performance in this prospective cohort, although larger comparative studies with longer follow-up are warranted.
Abstract
PURPOSE: To evaluate the visual and refractive outcomes in patients who underwent bilateral refractive lens exchange (RLE) with the trifocal hydrophobic FineVision HP IOL. METHODS: This prospective, single-center, non-comparative study enrolled 70 eyes of 35 patients implanted bilaterally with the FineVision HP IOL (Beaver-Visitec International, Inc. USA). Postoperative outcomes at 3 months included manifest refraction, monocular and binocular logMAR uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), distance-corrected intermediate visual acuity (DCIVA, at 60 cm), and distance-corrected near visual acuity (DCNVA, at 40 cm). The binocular defocus curve was also registered. RESULTS: 94.29% of eyes showed a spherical equivalent within ±0.50D and all within ±1.00D. 95.71% of eyes showed a refractive cylinder of ≤0.50D and all ≤1.00D. The mean spherical equivalent and refractive cylinder were 0.16 ± 0.27D and -0.18 ± 0.21D, respectively. Mean binocular CDVA, DCIVA and DCNVA were -0.12 ± 0.06, 0.15 ± 0.07 and 0.03 ± 0.05 logMAR, respectively. 88.57% and 100% of patients achieved a cumulative binocular CDVA of ≥20/16 and ≥20/20, respectively. Furthermore, 51.43% and 91.43% patients achieved a cumulative binocular DCIVA of ≥20/25 and ≥20/32, respectively; and 71.43% and 100% of patients achieved a cumulative binocular DCNVA of ≥20/20 and ≥20/25, respectively. The safety and efficacy indexes were 1.07 and 1.01, respectively. The defocus curve showed a peak of maximum visual acuity, better than 20/16, at distance, with a continuous smooth reduction in visual acuity for intermediate distances, followed by a secondary peak close to 20/20 at near. CONCLUSIONS: The FineVision HP IOL demonstrated favorable short-term refractive accuracy and visual performance in this prospective cohort, although larger comparative studies with longer follow-up are warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical Outcomes of the First Diffractive Trifocal Intraocular Lens: A Literature Review.Clinical ophthalmology (Auckland, N.Z.) · 2026
- A One-Year Visual and Safety Evaluation of a Newly Available Trifocal Intraocular Lens in Patients With Bilateral Cataracts: Clinical Outcomes From a Prospective Study.Journal of ophthalmology · 2026
- Visual Performance, Optical Quality, and Patient-Reported Outcomes After Trifocal Lens Implantation in Patients With Clear Lens or Early Cataract.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Hydrophobic Acrylic Trifocal IOL in Post-Laser Refractive Surgery Eyes: Visual Performance, Predictability, and Patient-Reported Outcomes.Journal of ophthalmology · 2026
- Comparative Clinical Outcomes Between Successive Generations of Liberty Trifocal Intraocular Lenses.Journal of clinical medicine · 2026
- Comparison of visual quality between the refractive-diffractive hybrid bifocal EDOF and the refractive-diffractive hybrid trifocal IOL.Frontiers in medicine · 2026