Changes in Left Ventricular Mechanics 6 Months After Bronchoscopic Lung Volume Reduction with Endobronchial Valves: A Prospective Exploratory Study.

Han Wang, Zhoufan Li, Mingming Deng, Gang Hou

Department of Pulmonary and Critical Care Medicine, The Second Affiliated Hospital of Harbin Medical University, Harbin Medical University, Harbin, People's Republic of China. · National Centre for Respiratory Medicine; State Key Laboratory of Respiratory Health and Multimorbidity; National Clinical Research Centre for Respiratory Diseases; Institute of Respiratory Medicine, Chinese Academy of Medical Sciences; Department of Pulmonary and Critical Care Medicine, Centre of Respiratory Medicine, China-Japan Friendship Hospital, Beijing, People's Republic of China.

Observational · n=18

Key points

From the paper's conclusion
  • In this prospective single-arm exploratory study, LVEF did not change significantly after BLVR. BLVR was associated with improved pulmonary and clinical outcomes and changes in selected LV strain-rate parameters. Due to the small sample size (n=18) and the single arm design, the results are exploratory only. Multidimensional STE may detect loading-related cardiac adaptation after reduced hyperinflation, but controlled confirmation is required.

Abstract

PURPOSE: Bronchoscopic lung volume reduction (BLVR) with endobronchial valves improves hyperinflation and functional outcomes in select patients with severe emphysema, but its effects on left ventricular (LV) mechanics remain insufficiently defined. In this study, multidimensional LV deformation before and after BLVR was evaluated using speckle-tracking echocardiography (STE). PATIENTS AND METHODS: This prospective, single-centre, single-arm pilot study included 18 patients with severe emphysema who completed baseline and 6-month two-dimensional STE after BLVR. Longitudinal, radial, and circumferential strain and strain-rate parameters, pulmonary function, target-lobe volume, 6-minute walk distance (6-MWD), dyspnoea, and health-related quality of life were assessed. For post hoc exploratory subgroup analyses, clinical responders were defined as patients with a ≥25 m increase in 6-MWD. RESULTS: At 6 months, BLVR improved pulmonary and clinical outcomes LVEF changed from 65.50 ± 4.59% to 67.06 ± 3.10% (mean paired change 1.56 percentage points, 95% CI -1.25 to 4.36; unadjusted P=0.259). Absolute LV global longitudinal strain increased by 0.91 percentage points (95% CI 0.11 to 1.70; BH-adjusted P=0.065), and four strain-rate parameters (LV GLSR-E, GLSR-A, GRSR-E, and GRSR-A) changed after BH correction. CONCLUSION: In this prospective single-arm exploratory study, LVEF did not change significantly after BLVR. BLVR was associated with improved pulmonary and clinical outcomes and changes in selected LV strain-rate parameters. Due to the small sample size (n=18) and the single arm design, the results are exploratory only. Multidimensional STE may detect loading-related cardiac adaptation after reduced hyperinflation, but controlled confirmation is required. CLINICAL TRIAL REGISTRATION: NCT05775588.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Changes in Left Ventricular Mechanics 6 Months After Bronchoscopic Lung Volume Reduction with Endobronchial Valves: A Prospective Exploratory Study — Science Skim