Real-Time Invasive Hemodynamic Changes During Endobronchial Valve Therapy in Advanced Emphysema: A Prospective Case Series.
Ciaran Grafton-Clarke, James Harrison, Della Mantle, Gareth Matthews, Pankaj Garg, Vasileios Kouritas, Henry O'Connor
School of Medicine University of East Anglia Norwich UK. · Department of Anaesthetics and Critical Care Norfolk and Norwich University Hospitals NHS Foundation Trust Norwich UK.
Key points
From the paper's conclusion- Real‐time invasive hemodynamic assessment during EBV implantation was feasible in this four‐patient case series and showed descriptive, hypothesis‐generating reductions in pulmonary vascular load in selected patients with advanced emphysema and baseline pre‐capillary PH.
Abstract
Pulmonary hypertension (PH) in advanced emphysema is associated with worse outcomes and often prompts caution or exclusion from bronchoscopic lung volume reduction. The immediate pulmonary hemodynamic response to endobronchial valve (EBV) deployment has not been characterized using invasive measurements obtained during implantation. We performed a prospective single-center physiological case series of four consecutive patients undergoing clinically indicated EBV therapy with concurrent right heart catheterization and continuous systemic arterial pressure monitoring. Hemodynamics were sampled at end-expiration at four predefined timepoints: pre-general anesthesia (pre-GA), GA pre-valve, GA post-valve, and post-extubation once awake and hemodynamically stable. Cardiac output was estimated by the indirect Fick method using an assumed oxygen consumption. All patients met hemodynamic criteria for PH with a pre-capillary profile at baseline. In the prespecified GA comparison (pre-valve to post-valve), mean pulmonary artery pressure (mPAP) decreased in all four patients (-10% to -61%). In the prespecified awake comparison (pre-GA to post-extubation), mPAP decreased in all four (-33% to -58%), with post-extubation mPAP < 20 mmHg in three patients. Estimated pulmonary vascular resistance decreased in three under GA (-42% to -90%) and in all four in the awake comparison (-47% to -96%); pulmonary arterial compliance increased in all four. Real-time invasive hemodynamic assessment during EBV implantation was feasible in this four-patient case series and showed descriptive, hypothesis-generating reductions in pulmonary vascular load in selected patients with advanced emphysema and baseline pre-capillary PH.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Valve Expectoration After Endobronchial Valve Placement: Potential Utility of Computed Tomography-Based Airway Sizing-A Case Report.Respirology case reports · 2026
- Exercise Stress Echocardiographic Assessment of Exercise-Induced Pulmonary Hypertension in Patients with Chronic Thromboembolic Pulmonary Hypertension after Balloon Pulmonary Angioplasty.The American journal of cardiology · 2026
- Changes in Left Ventricular Mechanics 6 Months After Bronchoscopic Lung Volume Reduction with Endobronchial Valves: A Prospective Exploratory Study.International journal of chronic obstructive pulmonary disease · 2026
- Invasive RV pressure-volume loops show hemodynamic benefits of reducing lung hyperinflation in COPD.Respiratory medicine and research · 2026
- Mechanistic haemodynamic evaluation of balloon pulmonary angioplasty in chronic thromboembolic pulmonary hypertension using digital twin–derived right ventricular–pulmonary arterial couplingEuropean Heart Journal · 2026
- Association Between End-Tidal Carbon Dioxide and Pulmonary Artery Pulse Pressure During Veno-Arterial Extracorporeal Membrane Oxygenation with Impella®: A Retrospective Exploratory Study.Journal of clinical medicine · 2026