Successful Conversion of Collateral Ventilation Status Using the AeriSeal® System Enables Bronchoscopic Lung Volume Reduction with One-Way Valves: CONVERT Trial.
Michela Bezzi, Alvin J Ing, Thomas Egenod, Nicolas Guibert, Pallav L Shah, Samuel V Kemp, Felix Herth, Farzad Bashirzadeh,
Key points
From the paper's conclusion- AeriSeal effectively converts collateral ventilation status in most treated patients, enabling successful valve therapy with durable lobar volume reduction and acceptable safety.
Abstract
RATIONALE: Bronchoscopic lung volume reduction (BLVR) with endobronchial valves is effective primarily in patients without collateral ventilation (CV-), leaving limited options for patients with collateral ventilation (CV+) in the target lobe. AeriSeal, delivered bronchoscopically, may occlude collateral channels and enable subsequent valve treatment. OBJECTIVES: To prospectively evaluate whether AeriSeal can convert target lobes from CV+ to CV- status in severe emphysema, enabling subsequent treatment with Zephyr valves. METHODS: Patients with severe COPD/emphysema, fissure completeness ≥80% on quantitative CT, and Chartis-confirmed collateral ventilation-positive (CV+) status were enrolled. Eligible subjects had fissure defects involving no more than three segmental airways. AeriSeal foam (≤40 mL) was administered bronchoscopically in one or two sessions, and CV status was reassessed after 6 weeks. Subjects converting to CV- status underwent Zephyr valve placement. Primary endpoints were successful CV conversion and target lobe volume reduction (TLVR ≥350 mL) 45 days after valve implantation. MEASUREMENTS AND MAIN RESULTS: Among 101 subjects, 75/99 evaluable patients achieved CV conversion (75.8%; 95% exact CI, 66.1-83.8%). Following valve treatment, TLVR ≥350 mL was achieved in 64/72 evaluable subjects (88.9%; 95% exact CI, 79.3-95.1%), with mean TLVR of 1062.5 ± 676.2 mL at 45 days, sustained through 12 months. At 6 months, post-bronchodilator FEV₁ improved by 0.08 L, residual volume decreased by 0.49L, SGRQ improved by 6.4 points, and mMRC by 0.8 points. Common serious adverse events included post-acute inflammatory response (PAIR; 16.7%), pneumothorax (19.2% within 45 days post-valves), COPD exacerbation, and pneumonia. Three deaths occurred, including one probably valve-related. CONCLUSIONS: AeriSeal effectively converts collateral ventilation status in most treated patients, enabling successful valve therapy with durable lobar volume reduction and acceptable safety.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Changes in Left Ventricular Mechanics 6 Months After Bronchoscopic Lung Volume Reduction with Endobronchial Valves: A Prospective Exploratory Study.International journal of chronic obstructive pulmonary disease · 2026
- Bronchoscopic and Surgical Interventions for Patients With COPD: A State-of-the-Art Review.Respiratory care · 2026
- Autologous Blood Patch Pleurodesis Without Valve Removal for Persistent Air Leak After Bronchoscopic Lung Volume Reduction: A Case Report.Respirology case reports · 2026
- Safety and Feasibility of the Lung Volume Reduction Reverser System in Patients with Severe Emphysema: A First-in-Human Pilot Study.Respiration; international review of thoracic diseases · 2026
- Development of a Tool to Assess Competency in Bronchoscopic Lung Volume Reduction Via Endobronchial Valve Placement.Journal of bronchology & interventional pulmonology · 2026
- Valve Expectoration After Endobronchial Valve Placement: Potential Utility of Computed Tomography-Based Airway Sizing-A Case Report.Respirology case reports · 2026