Influence of Aging on the Torque Accuracy of Two Different Spring-Style Implant Torque Wrenches: An in vitro Study.
Gholamreza Esfahanizadeh, Azita Mazaheri Tehrani, Arash Zarbakhsh, Emad Khatib, Elham Ghaffari
Department of Prosthodontics, Dental Branch, Islamic Azad University, Tehran, Iran.
Key points
From the paper's conclusion- Within the limitations of this in vitro study, repeated mechanical aging significantly reduced torque accuracy at the upper torque limit, although the observed reductions were small in absolute terms and remained within commonly used clinical tolerance thresholds. These findings support routine monitoring and calibration of spring-type torque wrenches to maintain reliable torque delivery and implant stability.
Abstract
BACKGROUND AND AIMS: Accurate torque delivery is critical for achieving proper implant preload and preventing screw loosening, yet torque wrenches may lose precision with repeated clinical use. This study aimed to assess how aging influences the torque accuracy of spring-type dental torque wrenches. MATERIALS AND METHODS: Five new spring-type dental torque wrenches from Neodent® and Intra-Lock® were tested at their lower and upper torque limits. Torque was measured using a calibrated digital torque meter; each wrench was activated 10 times per setting, and the mean of three consistent readings was recorded. Mechanical aging was simulated through 1000 continuous tightening-loosening cycles at each wrench's maximum torque. Torque measurements were repeated after 500 and 1000 cycles following the same protocol. Data were analyzed using one-way ANOVA (α = 0.05). RESULTS: Both torque wrench brands showed a significant reduction in torque accuracy at the upper limit after 500 and 1000 mechanical aging cycles (p < 0.001). At 1000 cycles, upper-limit torque decreased by 0.67 N·cm (2.2%) for Intra-Lock and 0.55 N·cm (1.7%) for Neodent compared with baseline values. At the lower limit, a significant change was observed for Intra-Lock (p = 0.014), whereas no significant change was observed for Neodent (p = 0.132). Across all measurement stages, Neodent delivered significantly higher upper-limit torque than Intra-Lock (p = 0.020), whereas no significant difference was observed at the lower limit (p = 0.132). CONCLUSION: Within the limitations of this in vitro study, repeated mechanical aging significantly reduced torque accuracy at the upper torque limit, although the observed reductions were small in absolute terms and remained within commonly used clinical tolerance thresholds. These findings support routine monitoring and calibration of spring-type torque wrenches to maintain reliable torque delivery and implant stability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Torque Accuracy of Spring-Style Dental Torque Wrenches After Repeated Mechanical Loading and Sterilization: An In Vitro Study.International journal of dentistry · 2026
- A comparative analysis of efficacy of torque limiting devices provided by different dental implant manufacturersBMC Oral Health · 2026
- Effect of Tightening Protocol on Reverse Torque and Plastic Deformation of Dynamic and Conventional Titanium Abutment Screws.Bioengineering (Basel, Switzerland) · 2026
- Effect of Viewing Angle While Tightening on Torque Values in Beam-Type Torque Wrenches.Dentistry journal · 2026
- Influence of Different Surface Modifications on the Reverse Torque Values of Abutment Screws: An In Vitro Study.Journal of functional biomaterials · 2026
- Abutment screw preload verification: Calculation using tightening torque, loosening torque, and screw thread pitch versus actual measurement.The Journal of prosthetic dentistry · 2026